skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS

Journal Article · · Analytical Chemistry

The ability to directly measure uranium isotope ratios on environmental swipes has been achieved through a solution-based microextraction process and represents a significant advancement toward the development of a rapid method to analyze international nuclear safeguard samples. Here, a microextraction probe is lowered and sealed onto the swipe surface, and analytes within the sampling site (~8 mm2) are dissolved and extracted into a flowing solvent of 2% nitric acid (HNO3). The mobilized species are subsequently directed into an inductively coupled plasma-mass spectrometer (ICP-MS) for accurate and precise isotope ratio determination. This work highlights the novelty of the sampling mechanism, particularly with the direct coupling of the microextraction probe to the ICP-MS and measurement of uranium isotope ratios. The preliminary method detection limit for the microextraction-ICP-MS method, utilizing a quadrupole-based MS, was determined to be ~50 pg of 238U. Additionally, precise and accurate isotope ratio measurements were achieved on uranium reference materials for both the major (235U/238U) and minor (234U/238U and 236U/238U) ratios. While the present work is focused on directly measuring uranium isotopic systems on swipe surfaces for nuclear safeguards and verification applications, the benefits would extend across many applications in which direct solid sampling is sought for elemental and isotopic analysis.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1817511
Journal Information:
Analytical Chemistry, Vol. 93, Issue 32; ISSN 0003-2700
Publisher:
American Chemical Society (ACS)Copyright Statement
Country of Publication:
United States
Language:
English

References (26)

Recent applications of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for biological sample analysis: a follow-up review journal January 2017
Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry journal June 2018
The application of chemical modification in direct sample insertion inductively coupled plasma-atomic emission spectrometry journal January 1990
Electrothermal vaporization for sample introduction in atomic absorption, atomic emission and plasma mass spectrometry—a critical review with focus on solid sampling and slurry analysis journal January 2008
Automation of a Surface Sampling Probe/Electrospray Mass Spectrometry System journal November 2005
Laser Ablation in Analytical Chemistry journal May 2013
Liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasmas for diverse spectrochemical analysis applications journal January 2017
A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L journal July 2020
Uranium isotope analysis by MC-ICP-MS in sub-ng sized samples journal January 2016
Coupling of a high throughput microelectrochemical cell with online multielemental trace analysis by ICP-MS journal December 2011
Time and potential resolved dissolution analysis of rhodium using a microelectrochemical flow cell coupled to an ICP-MS journal July 2012
Direct sample insertion device for inductively coupled plasma emission spectrometry journal November 1979
Micro-capillary system coupled to ICP-MS as a novel technique for investigation of micro-corrosion processes journal January 2007
Determination of the isotopic composition of micrometric uranium particles by UV femtosecond laser ablation coupled with sector-field single-collector ICP-MS journal January 2017
Liquid Microjunction Surface Sampling Coupled with High-Pressure Liquid Chromatography−Electrospray Ionization-Mass Spectrometry for Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections journal July 2010
Preparation and certification of the uranium nitrate solution reference materials series IRMM-2019 to IRMM-2029 for the isotopic composition journal September 2018
LA-ICP-MS imaging in the geosciences and its applications to geochronology journal January 2021
Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections journal November 2009
Thin-Layer Chromatography and Electrospray Mass Spectrometry Coupled Using a Surface Sampling Probe journal November 2002
Electrochemical On‐line ICP‐MS in Electrocatalysis Research journal December 2018
Application of laser ablation inductively coupled plasma mass spectrometry for the isotopic analysis of single uranium particles journal September 2008
Spatially and time-resolved element-specific in situ corrosion investigations with an online hyphenated microcapillary flow injection inductively coupled plasma mass spectrometry set-up journal July 2008
Femtosecond laser ablation ICP-MS journal January 2002
Optimization of uranium and plutonium separations using TEVA and UTEVA cartridges for MC-ICP-MS analysis of environmental swipe samples journal June 2019
Application of Fission Track Technique for the Analysis of Individual Particles Containing Uranium in Safeguard Swipe Samples journal June 2004
Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source journal June 2020