Title: Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS

Journal Article · · Analytica Chimica Acta

Direct isotope ratio analysis of solid uranium particulates on cotton swipes was achieved using a solution-based microextraction technique, coupled to a quadrupole inductively coupled plasma - mass spectrometer (ICP-MS). This microextraction-ICP-MS methodology provides rapid isotopic analysis which could be applicable to nuclear safeguards measurements. Particulates of uranyl nitrate hexahydrate (UO2(NO3)2·6H2O) and uranyl fluoride (UO2F2) ranging from 6 μm to 40 μm in length were transferred to cotton swipes with a particle manipulator. The microextraction probe then delivers a 5% nitric acid (HNO3) solvent onto the swipe surface to extract the uranium species. The extracted sample is then delivered to the ICP-MS for isotopic determination. The majority of uranium signal (~99% and ~94% for UO2(NO3)2·6H2O and UO2F2, respectively) was detected in the first 15 s extraction, while subsequent extractions on the same location had low or no U signal, suggesting near complete removal of the solid uranium compounds from the swipe surface. Ten samples (for each of the uranium compounds), were analyzed for their isotopic composition. For UO2(NO3)2·6H2O, the determined isotope ratios resulted in a % relative difference (% RD) from the referenced isotope ratios of 0.97, 1.0, and 7.3% for 234U/238U, 235U/238U, and 236U/238U, respectively. The % RD of the UO2F2 isotope ratios were 1.9 and 0.60% for 234U/238U and 235U/238U, respectively. The preliminary limits of detection were determined to be 0.002, 0.4, and 60 pg for 234U, 235U and 238U, respectively This work demonstrates that microextraction ICP-MS is a rapid and sensitive method that could directly determine uranium isotope ratios of UO2(NO3)2·6H2O and UO2F2 particulates on cotton swipes.

Research Organization:
Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1870236
Journal Information:
Analytica Chimica Acta, Vol. 1209, Issue 1; ISSN 0003-2670
Publisher:
ElsevierCopyright Statement
Country of Publication:
United States
Language:
English

References (44)

Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interfering polyatomic species journal January 2008
Total evaporation measurements: experience with multi-collector instruments and a thermal ionization quadrupole mass spectrometer journal August 1995
Spatial distribution of uranium isotopes in solid nuclear materials using laser ablation multi-collector ICP-MS journal July 2018
Crystal chemical studies of the 5 f -series of elements. III. A study of the disorder in the crystal structure of anhydrous uranyl fluoride journal December 1948
Precise and accurate isotopic analysis of microscopic uranium-oxide grains using LA-MC-ICP-MS
  • Lloyd, Nicholas S.; Parrish, Randall R.; Horstwood, Matthew S. A.
  • Journal of Analytical Atomic Spectrometry, Vol. 24, Issue 6 https://doi.org/10.1039/b819373h
journal January 2009
Phase Equilibrium Studies for the Ternary System Uranyl Nitrate – Nitric acid – Water journal February 1963
Application of Nanosecond-UV Laser Ablation–Inductively Coupled Plasma Mass Spectrometry for the Isotopic Analysis of Single Submicrometer-Size Uranium Particles journal September 2011
Efficient Isotope Ratio Analysis of Uranium Particles in Swipe Samples by Total-Reflection X-ray Fluorescence Spectrometry and Secondary Ion Mass Spectrometry journal November 2004
An improved FT-TIMS method of measuring uranium isotope ratios in the uranium-bearing particles journal December 2015
Strengthening IAEA safeguards through environmental sampling and analysis journal June 1998
Coupling of a high throughput microelectrochemical cell with online multielemental trace analysis by ICP-MS journal December 2011
Total evaporation method for uranium isotope-amount ratio measurements journal January 2013
Experimental evaluation of the detection methods of thermal ionization mass spectrometry for isotopic analysis of ultra-trace level uranium journal March 2018
Time and potential resolved dissolution analysis of rhodium using a microelectrochemical flow cell coupled to an ICP-MS journal July 2012
Determination of the isotopic composition of single sub-micrometer-sized uranium particles by laser ablation coupled with multi-collector inductively coupled plasma mass spectrometry journal February 2019
Studies on analyzing single uranium-bearing particle by FT-TIMS journal March 2013
Fiji: an open-source platform for biological-image analysis journal June 2012
Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS journal July 2021
Study on analysis of isotopic ratio of uranium-bearing particle in swipe samples by FT-TIMS journal August 2008
Capabilities of laser ablation – ICP-TOF-MS coupling for isotopic analysis of individual uranium micrometric particles journal January 2018
Experimental and computational study of particle formation kinetics in UF 6 hydrolysis journal January 2020
Preparation and certification of the uranium nitrate solution reference materials series IRMM-2019 to IRMM-2029 for the isotopic composition journal September 2018
A neutron diffraction study of uranyl nitrate hexahydrate journal October 1965
Voltage required to detach an adhered particle by Coulomb interaction for micromanipulation journal July 2001
The use of LA-SF-ICP-MS for nuclear forensics purposes: uranium isotope ratio analysis journal August 2012
Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections journal November 2009
A kinematic model of preferred orientation journal January 1977
Mass spectrometric analysis for nuclear safeguards journal January 2015
Fully automated liquid extraction-based surface sampling and ionization using a chip-based robotic nanoelectrospray platform journal March 2010
Electrochemical On‐line ICP‐MS in Electrocatalysis Research journal December 2018
Contact Micromanipulation—Survey of Strategies journal August 2009
Application of laser ablation inductively coupled plasma mass spectrometry for the isotopic analysis of single uranium particles journal September 2008
Batch Crystallization of Uranyl Nitrate journal January 2012
Performance of laser ablation: quadrupole-based ICP-MS coupling for the analysis of single micrometric uranium particles journal September 2012
Promises and pitfalls of ns-laser ablation for depth profiling of UO2 single crystals journal November 2020
Electrostatic detachment of an adhering particle from a micromanipulated probe journal February 2003
Secondary ion mass spectrometry combined with alpha track detection for isotope abundance ratio analysis of individual uranium-bearing particles journal March 2014
Development in fission track-thermal ionization mass spectrometry for particle analysis of safeguards environmental samples journal May 2007
High-precision isotopic analyses of uranium and plutonium by total sample volatilization and signal integration journal January 1991
Direct uranium isotope ratio analysis of single micrometer-sized glass particles journal November 2012
Coupling of a scanning flow cell with online electrochemical mass spectrometry for screening of reaction selectivity journal October 2014
Evaluation strategies for isotope ratio measurements of single particles by LA-MC-ICPMS journal January 2013
Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS journal January 2021
Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source journal June 2020