Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Analysis of solid uranium particulates on cotton swipes with an automated microextraction-ICP-MS system

Journal Article · · Analytical Methods
DOI:https://doi.org/10.1039/d2ay01394k· OSTI ID:1899833

Here, an automated microextraction method coupled to an inductively coupled plasma – mass spectrometer (ICP-MS) was developed for the direct analysis of solid uranium particulates on the surface of cotton swipes. The microextraction probe extracts particulates from the sample surface, in a flowing solvent, and directs the removed analyte to an ICP-MS for isotopic determination. The automated system utilizes a mechanical XY stage that is software controlled with the capability of saving and returning to specific locations and a camera focused to the swipe surface for optimal viewing of the extracted locations (i.e., material present). Here, particulates (n = 135) were extracted and measured by ICP-MS, including 35 depleted uranyl nitrate hexahydrate (UN) (used for mass bias corrections), 50 uranyl fluoride (UO2F2), and 50 uranyl acetate (UAc) particulates. Blank extractions were performed on the cotton swipes between triplicate sample analyses. Between each swipe extraction, the probe was sent between two wells containing 10% and 5% HNO3 to clean the probe head and to eliminate any analyte carryover between particulates. The measured 235U/238U and 234U/238U isotope ratios for the UO2F2 particulates were 0.00725(8) and 0.000054(4), a percent relative difference (% RD) of –0.041% and –1.7% from the reference isotope ratios determined in-lab through multi-collector ICP-MS analysis of dissolved aliquots of the U material. The UAc samples had a measured 235U/238U isotope ratio of 0.00206(7), a –0.96% relative difference from the reference value of 0.00208(1). The 234U/238U and 236U/238U isotope ratios were 0.000008(1) and 0.000031(4), –5.1% RD and –4.3% RD, respectively. The automated sample stage enabled seamless and rapid particle analysis, leading to a significant increase in throughput versus what was previously possible. Additionally, the saved location capability reduced user sampling error as sampling locations were easily stored and recalled. Analysis of U particles on the swipe surface – including blanks, mass bias, and triplicate extractions – was completed in less than an hour without any sample preparation necessary.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1899833
Alternate ID(s):
OSTI ID: 1896328
Journal Information:
Analytical Methods, Journal Name: Analytical Methods Journal Issue: 44 Vol. 14; ISSN 1759-9660
Publisher:
Royal Society of ChemistryCopyright Statement
Country of Publication:
United States
Language:
English

References (40)

Determination of the isotopic composition of single sub-micrometer-sized uranium particles by laser ablation coupled with multi-collector inductively coupled plasma mass spectrometry journal February 2019
Nuclear safeguards applications using LG-SIMS with automated screening capabilities journal May 2012
Performance of laser ablation: quadrupole-based ICP-MS coupling for the analysis of single micrometric uranium particles journal September 2012
Novel sample introduction system to reduce ICP-OES sample size for plutonium metal trace impurity determination journal December 2015
Establishment of environmental sampling baseline of a nuclear facility using large geometry-secondary ion mass spectrometry (LG-SIMS) journal November 2020
Crystal and molecular structure of uranyl acetate dihydrate journal September 1975
Strengthening IAEA safeguards through environmental sampling and analysis journal June 1998
Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS journal May 2022
Development of a fast and efficient analytical technique for the isotopic analysis of fission and actinide elements in environmental matrices journal February 2019
Direct uranium isotope ratio analysis of single micrometer-sized glass particles journal November 2012
Studies on analyzing single uranium-bearing particle by FT-TIMS journal March 2013
An improved FT-TIMS method of measuring uranium isotope ratios in the uranium-bearing particles journal December 2015
Rapid and automated separation of uranium ore concentrates for trace element analysis by inductively coupled plasma – optical emission spectroscopy/triple quadrupole mass spectrometry journal May 2021
An automated micro-separation system for the chromatographic removal of uranium matrix for trace element analysis by ICP-OES journal November 2018
Rapid concentration and isotopic measurements of ultra-trace 235U fission products with comparison to an ORIGEN isotope depletion model journal December 2019
Quantification of uranium, plutonium, neodymium and gadolinium for the characterization of spent nuclear fuel using isotope dilution HPIC-SF-ICP-MS journal January 2021
Prompt digestion and HPIC separation of rare earth elements in surrogate post-detonation debris material with detection by ICP-MS and gamma spectroscopy journal December 2022
Recent contributions to the rapid screening of radionuclides in emergency responses and nuclear forensics journal December 2016
Application of Nanosecond-UV Laser Ablation–Inductively Coupled Plasma Mass Spectrometry for the Isotopic Analysis of Single Submicrometer-Size Uranium Particles journal September 2011
Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source journal June 2020
Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS journal July 2021
Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry journal June 2018
Nuclear Forensic Science: Correlating Measurable Material Parameters to the History of Nuclear Material journal October 2012
Fiji: an open-source platform for biological-image analysis journal June 2012
Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interfering polyatomic species journal January 2008
Improved particle location and isotopic screening measurements of sub-micron sized particles by Secondary Ion Mass Spectrometry journal January 2011
Detection of traces of fluorine in micrometer sized uranium bearing particles using SIMS journal January 2014
Mass spectrometric analysis for nuclear safeguards journal January 2015
Liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasmas for diverse spectrochemical analysis applications journal January 2017
Capabilities of laser ablation – ICP-TOF-MS coupling for isotopic analysis of individual uranium micrometric particles journal January 2018
Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS journal January 2021
Total evaporation method for uranium isotope-amount ratio measurements journal January 2013
The use of solution nebulization ICP-MS combined with particle screening and micro-sampling for analysis of individual uranium-bearing particles journal January 2013
Crystal chemical studies of the 5 f -series of elements. III. A study of the disorder in the crystal structure of anhydrous uranyl fluoride journal December 1948
A neutron diffraction study of uranyl nitrate hexahydrate journal October 1965
A kinematic model of preferred orientation journal January 1977
Trace Elemental Analysis of Bulk Thorium Using an Automated Separation–Inductively Coupled Plasma Optical Emission Spectroscopy Methodology journal October 2020
Automated mineralogy and petrology - applications of TESCAN Integrated Mineral Analyzer (TIMA) journal May 2018
Overview of Algorithms for Using Particle Morphology in Pre-Detonation Nuclear Forensics journal November 2021
Rare Earth Element Determination in Uranium Ore Concentrates Using Online and Offline Chromatography Coupled to ICP-MS journal January 2020

Similar Records

Direct isotopic analysis of solid uranium particulates on cotton swipes by microextraction-ICP-MS
Journal Article · Sat Apr 23 00:00:00 EDT 2022 · Analytica Chimica Acta · OSTI ID:1870236

Related Subjects