Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

Journal Article · · Journal of Analytical Atomic Spectrometry
DOI:https://doi.org/10.1039/d1ja00255d· OSTI ID:1824979

This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm2), and delivers solvent (2% HNO3) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition (240Pu/239Pu and 242Pu/239Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240Pu/239Pu ratio on all three CRMs and <10% for the 242Pu/239Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240Pu/239Pu and <15% for the 242Pu/239Pu. Method limits of detection were determined, based on measurements of an enriched 244Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.

Research Organization:
Oak Ridge National Laboratory (ORNL), Oak Ridge, TN (United States)
Sponsoring Organization:
USDOE National Nuclear Security Administration (NNSA)
Grant/Contract Number:
AC05-00OR22725
OSTI ID:
1824979
Alternate ID(s):
OSTI ID: 1820479
Journal Information:
Journal of Analytical Atomic Spectrometry, Journal Name: Journal of Analytical Atomic Spectrometry Journal Issue: 10 Vol. 36; ISSN 0267-9477
Publisher:
Royal Society of ChemistryCopyright Statement
Country of Publication:
United States
Language:
English

References (37)

Rapid paper spray mass spectrometry characterization of uranium and exemplar molecular species journal October 2019
Ambient desorption/ionization mass spectrometry using a liquid sampling–atmospheric glow discharge (LS-APGD) ionization source journal July 2013
Round-robins in the area of uranium and plutonium bulk analysis of environmental samples journal August 2012
Integration of a hyphenated HPIC-ICPMS protocol for the measurement of transplutonium isotopic mass distributions for 252Cf campaigns at Oak Ridge National Laboratory journal August 2018
Preparation and certification of the uranium nitrate solution reference materials series IRMM-2019 to IRMM-2029 for the isotopic composition journal September 2018
A highly-enriched 244Pu reference material for nuclear safeguards and nuclear forensics measurements journal March 2020
Strengthening IAEA safeguards through environmental sampling and analysis journal June 1998
Characterizing uranium oxide reference particles for isotopic abundances and uranium mass by single particle isotope dilution mass spectrometry journal October 2012
Feasibility study on evaluating uranium enrichment with the High Resolution Gamma-Ray Spectrometry and X-ray fluorescence journal June 2019
Development of a fast and efficient analytical technique for the isotopic analysis of fission and actinide elements in environmental matrices journal February 2019
Direct uranium isotope ratio analysis of single micrometer-sized glass particles journal November 2012
Rapid determination of ultra-trace plutonium in large volume of urine samples by tandem quadrupole inductively coupled plasma-mass spectrometry journal October 2021
Inductively coupled plasma-sector field mass spectrometry with a high-efficiency sample introduction system for the determination of Pu isotopes in settling particles at femtogram levels journal July 2006
Particle isolation for analysis of uranium minor isotopes in individual particles by secondary ion mass spectrometry journal February 2007
Optimization of uranium and plutonium separations using TEVA and UTEVA cartridges for MC-ICP-MS analysis of environmental swipe samples journal June 2019
Quantification of uranium, plutonium, neodymium and gadolinium for the characterization of spent nuclear fuel using isotope dilution HPIC-SF-ICP-MS journal January 2021
Peer Reviewed: Strengthened Nuclear Safeguards journal January 2002
Automation of a Surface Sampling Probe/Electrospray Mass Spectrometry System journal November 2005
Liquid Microjunction Surface Sampling Coupled with High-Pressure Liquid Chromatography−Electrospray Ionization-Mass Spectrometry for Analysis of Drugs and Metabolites in Whole-Body Thin Tissue Sections journal July 2010
Application of a Liquid Extraction Based Sealing Surface Sampling Probe for Mass Spectrometric Analysis of Dried Blood Spots and Mouse Whole-Body Thin Tissue Sections journal November 2009
Rapid Determination of Uranium Isotopic Abundance from Cotton Swipes: Direct Extraction via a Planar Surface Reader and Coupling to a Microplasma Ionization Source journal June 2020
Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS journal July 2021
Automated Separation of Uranium and Plutonium from Environmental Swipe Samples for Multiple Collector Inductively Coupled Plasma Mass Spectrometry journal June 2018
Intercomparison of the Radio-Chronometric Ages of Plutonium-Certified Reference Materials with Distinct Isotopic Compositions journal August 2019
A preliminary investigation into the use of molecular oxide and hydride secondary ion relationships for improvement of the 236U/238U determination on a NanoSIMS 50L journal July 2020
Ultratrace determination of uranium and plutonium by nano-volume flow injection double-focusing sector field inductively coupled plasma mass spectrometry (nFI–ICP-SFMS) journal January 2005
Assessment of plutonium measurement in the femtogram range by ICP-MS; correction from interfering polyatomic species journal January 2008
Mass spectrometric analysis for nuclear safeguards journal January 2015
Determination of the isotopic composition of micrometric uranium particles by UV femtosecond laser ablation coupled with sector-field single-collector ICP-MS journal January 2017
Uranium isotope analysis by MC-ICP-MS in sub-ng sized samples journal January 2016
Liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasmas for diverse spectrochemical analysis applications journal January 2017
Laser ablation – inductively couple plasma – mass spectrometry/laser induced break down spectroscopy: a tandem technique for uranium particle characterization journal January 2017
Determination of picogram amounts of uranium in micrometre-sized particles by isotope dilution mass spectrometry journal January 2021
Rapid determination of plutonium in urine using flow injection on-line preconcentration and inductively coupled plasma mass spectrometry journal January 2005
241Am INGROWTH AND ITS EFFECT ON INTERNAL DOSE journal January 2016
Application of Fission Track Technique for the Analysis of Individual Particles Containing Uranium in Safeguard Swipe Samples journal June 2004
Evaluation of a new sector-field ICP-MS with Jet Interface for ultra-trace determination of Pu isotopes: from femtogram to attogram levels journal January 2015

Similar Records

Microextraction–TQ–ICP–MS for the Direct Analysis of U and Pu from Cotton Swipes
Journal Article · Fri Oct 06 00:00:00 EDT 2023 · Analytical Chemistry · OSTI ID:2205442

Assessment of Low-Level Pu Isotope Ratio Measurements Using Multicollector Inductively Coupled Plasma Mass Spectrometry (MC-ICP-MS/MS) Equipped with a Pre-Mass Filter
Journal Article · Fri Sep 12 00:00:00 EDT 2025 · Applied Spectroscopy Practica · OSTI ID:3002509

Direct Uranium Isotopic Analysis of Swipe Surfaces by Microextraction-ICP-MS
Journal Article · Thu Jul 08 00:00:00 EDT 2021 · Analytical Chemistry · OSTI ID:1817511