DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images

Abstract

Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multimonochromatic x-ray imager, MMI, records the spectral signature from an ICF implosion core with time resolution, 2D spatial resolution and spectral resolution. While narrow-band images and 2D space-resolved spectra from the MMI data constrain the temperature and the density spatial structure of the core, the accuracy of the images and the spectra highly depends on the quality of the MMI data and the processing tools. Here, we synthetically investigate the criterion for reliable MMI diagnostics and its effects on the accuracy of the reconstructed images. The pinhole array tilt determines the object spatial sampling efficiency and the minimum reconstruction width, $$\textit{w}$$. When the spectral width associated with $$\textit{w}$$ is significantly narrower than the spectral linewidth, the line images reconstructed from the MMI data become reliable. The MMI setup has to be optimized for every application to meet this criterion for reliable ICF diagnostics.

Authors:
 [1];  [2];  [2];  [3];  [4]
  1. Univ. of Nevada, Reno, NV (United States). Dept. of Physics; Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)
  2. Univ. of Nevada, Reno, NV (United States). Dept. of Physics
  3. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  4. Univ. de Las Palmas de Gran Canaria (Spain). Dept. de Fisica
Publication Date:
Research Org.:
Sandia National Lab. (SNL-NM), Albuquerque, NM (United States); Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE National Nuclear Security Administration (NNSA)
OSTI Identifier:
1512877
Alternate Identifier(s):
OSTI ID: 1879281
Report Number(s):
SAND-2015-3156J; LLNL-JRNL-838007
Journal ID: ISSN 2095-4719; applab; 662161
Grant/Contract Number:  
AC04-94AL85000; NA0000859; NA0002267; AC52-07NA27344
Resource Type:
Accepted Manuscript
Journal Name:
High Power Laser Science and Engineering
Additional Journal Information:
Journal Volume: 3; Journal ID: ISSN 2095-4719
Publisher:
Cambridge University Press
Country of Publication:
United States
Language:
English
Subject:
47 OTHER INSTRUMENTATION; high power laser; inertial confinement fusion; monochromatic imager; x-ray diagnostics; 70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Citation Formats

Nagayama, Taisuke, Mancini, Roberto C, Mayes, D., Tommasini, R., and Florido, R. An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images. United States: N. p., 2015. Web. doi:10.1017/hpl.2015.25.
Nagayama, Taisuke, Mancini, Roberto C, Mayes, D., Tommasini, R., & Florido, R. An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images. United States. https://doi.org/10.1017/hpl.2015.25
Nagayama, Taisuke, Mancini, Roberto C, Mayes, D., Tommasini, R., and Florido, R. Tue . "An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images". United States. https://doi.org/10.1017/hpl.2015.25. https://www.osti.gov/servlets/purl/1512877.
@article{osti_1512877,
title = {An important criterion for reliable multi-monochromatic x-ray imager diagnostics and its impact on the reconstructed images},
author = {Nagayama, Taisuke and Mancini, Roberto C and Mayes, D. and Tommasini, R. and Florido, R.},
abstractNote = {Temperature and density asymmetry diagnosis is critical to advance inertial confinement fusion (ICF) science. A multimonochromatic x-ray imager, MMI, records the spectral signature from an ICF implosion core with time resolution, 2D spatial resolution and spectral resolution. While narrow-band images and 2D space-resolved spectra from the MMI data constrain the temperature and the density spatial structure of the core, the accuracy of the images and the spectra highly depends on the quality of the MMI data and the processing tools. Here, we synthetically investigate the criterion for reliable MMI diagnostics and its effects on the accuracy of the reconstructed images. The pinhole array tilt determines the object spatial sampling efficiency and the minimum reconstruction width, $\textit{w}$. When the spectral width associated with $\textit{w}$ is significantly narrower than the spectral linewidth, the line images reconstructed from the MMI data become reliable. The MMI setup has to be optimized for every application to meet this criterion for reliable ICF diagnostics.},
doi = {10.1017/hpl.2015.25},
journal = {High Power Laser Science and Engineering},
number = ,
volume = 3,
place = {United States},
year = {Tue Aug 25 00:00:00 EDT 2015},
month = {Tue Aug 25 00:00:00 EDT 2015}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 3 works
Citation information provided by
Web of Science

Figures / Tables:

FIG. 1 FIG. 1: (a) The signal collected through a pinhole is proportional to the source-to-pinhole solid angle, (b) spatial resolution is determined by object-pinhole-detector distances, (c) magnification is determined by object-pinhole distance, p, and object-detector distance, L. Optimal pinhole separation, l, is determined so that images of size FM do notmore » overlap.« less

Save / Share:

Works referenced in this record:

Review of the National Ignition Campaign 2009-2012
journal, February 2014

  • Lindl, John; Landen, Otto; Edwards, John
  • Physics of Plasmas, Vol. 21, Issue 2
  • DOI: 10.1063/1.4865400

The physics basis for ignition using indirect-drive targets on the National Ignition Facility
journal, February 2004

  • Lindl, John D.; Amendt, Peter; Berger, Richard L.
  • Physics of Plasmas, Vol. 11, Issue 2
  • DOI: 10.1063/1.1578638

The flexible atomic code
journal, May 2008

  • Gu, M. F.
  • Canadian Journal of Physics, Vol. 86, Issue 5
  • DOI: 10.1139/p07-197

Multispectral x-ray imaging with a pinhole array and a flat Bragg mirror
journal, July 2005

  • Koch, J. A.; Barbee, T. W.; Izumi, N.
  • Review of Scientific Instruments, Vol. 76, Issue 7
  • DOI: 10.1063/1.1940614

Lowering of Ionization Potentials in Plasmas
journal, April 1966

  • Stewart, John C.; Pyatt, Kedar D. , Jr.
  • The Astrophysical Journal, Vol. 144
  • DOI: 10.1086/148714

Multispectral x-ray imaging for core temperature and density maps retrieval in direct drive implosions
journal, October 2006

  • Tommasini, Riccardo; Koch, Jeffrey A.; Izumi, Nobuhiko
  • Review of Scientific Instruments, Vol. 77, Issue 10
  • DOI: 10.1063/1.2218856

Escape factors for Stark-broadened line profiles
journal, July 1987

  • Mancini, R. C.; Joyce, R. F.; Hooper, C. F.
  • Journal of Physics B: Atomic and Molecular Physics, Vol. 20, Issue 13
  • DOI: 10.1088/0022-3700/20/13/011

Processing of spectrally resolved x-ray images of inertial confinement fusion implosion cores recorded with multimonochromatic x-ray imagers
journal, May 2011

  • Nagayama, T.; Mancini, R. C.; Florido, R.
  • Journal of Applied Physics, Vol. 109, Issue 9
  • DOI: 10.1063/1.3580513

Investigation of a polychromatic tomography method for the extraction of the three-dimensional spatial structure of implosion core plasmas
journal, August 2012

  • Nagayama, T.; Mancini, R. C.; Florido, R.
  • Physics of Plasmas, Vol. 19, Issue 8
  • DOI: 10.1063/1.4743017

Processing of multi-monochromatic x-ray images from indirect drive implosions at OMEGA
journal, March 2003

  • Welser, L. A.; Mancini, R. C.; Koch, J. A.
  • Review of Scientific Instruments, Vol. 74, Issue 3
  • DOI: 10.1063/1.1535278

Calculational aspects of the Stark line broadening of multielectron ions in plasmas
journal, February 1991


Comparison of genetic-algorithm and emissivity-ratio analyses of image data from OMEGA implosion cores
journal, October 2008

  • Nagayama, T.; Mancini, R. C.; Florido, R.
  • Review of Scientific Instruments, Vol. 79, Issue 10
  • DOI: 10.1063/1.2966370

Radiation hydrodynamics modeling of the highest compression inertial confinement fusion ignition experiment from the National Ignition Campaign
journal, February 2015

  • Clark, D. S.; Marinak, M. M.; Weber, C. R.
  • Physics of Plasmas, Vol. 22, Issue 2
  • DOI: 10.1063/1.4906897

Reconstruction of quasimonochromatic images for multispectral x-ray imaging with a pinhole array and a flat Bragg mirror
journal, August 2006

  • Izumi, N.; Barbee, T. W.; Koch, J. A.
  • Review of Scientific Instruments, Vol. 77, Issue 8
  • DOI: 10.1063/1.2336194

Dopant radiative cooling effects in indirect-drive Ar-doped capsule implosion experiments
journal, December 2005


Laser Compression of Matter to Super-High Densities: Thermonuclear (CTR) Applications
journal, September 1972

  • Nuckolls, John; Wood, Lowell; Thiessen, Albert
  • Nature, Vol. 239, Issue 5368, p. 139-142
  • DOI: 10.1038/239139a0

Works referencing / citing this record:

Impact of 3D effects on the characteristics of a multi-monochromatic x-ray imager
journal, January 2019


Figures/Tables have been extracted from DOE-funded journal article accepted manuscripts.