Title: Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

Abstract

The InfraRed imaging Video Bolometer measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 x 480 (1280 x 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm x 9 cm x 2 μm Pt foil. The foil is divided into 40 x 40 (64 x 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm2 for a time resolution of 33 (20) ms. Synthetic images derived from SOLPS data using the IRVB geometry show peak signal levels ranging from ~0.8 - ~80 (~0.36 - ~26) mW/cm2.

Authors:
 [1];  [2];  [3];  [3];  [4];  [3];  [1];  [3]; ORCiD logo [5];  [4]
  1. National Inst. for Fusion Science, Toki (Japan); Graduate Univ. for Advance Studies (SOKENDAI), Toki (Japan)
  2. National Inst. for Quantum and Radiological Science and Technology, Naka, Ibaraki (Japan)
  3. Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)
  4. Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
  5. Dutch Foundation for Fundamental Research on Matter (FOM), Eindhoven (The Netherlands). Dutch Inst. for Fundamental Energy Research (DIFFER)
Publication Date:
Research Org.:
Princeton Plasma Physics Lab. (PPPL), Princeton, NJ (United States)
Sponsoring Org.:
USDOE; National Institute for Fusion Science (Japan); National Institutes for Natural Sciences (Japan)
OSTI Identifier:
1368172
Grant/Contract Number:  
AC02-09CH11466; AC05-00OR22725
Resource Type:
Accepted Manuscript
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 87; Journal Issue: 11; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English
Subject:
47 OTHER INSTRUMENTATION

Citation Formats

Peterson, B. J., Sano, R., Reinke, M. L., Canik, J. M., Delgado-Aparicio, L. F., Lore, J. D., Mukai, K., Gray, T. K., van Eden, G. G., and Jaworski, M. A. Preliminary design of a tangentially viewing imaging bolometer for NSTX-U. United States: N. p., 2016. Web. doi:10.1063/1.4955278.
Peterson, B. J., Sano, R., Reinke, M. L., Canik, J. M., Delgado-Aparicio, L. F., Lore, J. D., Mukai, K., Gray, T. K., van Eden, G. G., & Jaworski, M. A. Preliminary design of a tangentially viewing imaging bolometer for NSTX-U. United States. https://doi.org/10.1063/1.4955278
Peterson, B. J., Sano, R., Reinke, M. L., Canik, J. M., Delgado-Aparicio, L. F., Lore, J. D., Mukai, K., Gray, T. K., van Eden, G. G., and Jaworski, M. A. Wed . "Preliminary design of a tangentially viewing imaging bolometer for NSTX-U". United States. https://doi.org/10.1063/1.4955278. https://www.osti.gov/servlets/purl/1368172.
@article{osti_1368172,
title = {Preliminary design of a tangentially viewing imaging bolometer for NSTX-U},
author = {Peterson, B. J. and Sano, R. and Reinke, M. L. and Canik, J. M. and Delgado-Aparicio, L. F. and Lore, J. D. and Mukai, K. and Gray, T. K. and van Eden, G. G. and Jaworski, M. A.},
abstractNote = {The InfraRed imaging Video Bolometer measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 x 480 (1280 x 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm x 9 cm x 2 μm Pt foil. The foil is divided into 40 x 40 (64 x 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm2 for a time resolution of 33 (20) ms. Synthetic images derived from SOLPS data using the IRVB geometry show peak signal levels ranging from ~0.8 - ~80 (~0.36 - ~26) mW/cm2.},
doi = {10.1063/1.4955278},
journal = {Review of Scientific Instruments},
number = 11,
volume = 87,
place = {United States},
year = {Wed Aug 03 00:00:00 EDT 2016},
month = {Wed Aug 03 00:00:00 EDT 2016}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 3 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Calibration and sensitivity of the infrared imaging video bolometer
journal, March 2003

  • Peterson, B. J.; Kostrioukov, A. Yu.; Ashikawa, N.
  • Review of Scientific Instruments, Vol. 74, Issue 3
  • DOI: 10.1063/1.1537031

Foil Calibration for IR Imaging Bolometer by Laser Irradiation
journal, January 2012

  • Sano, Ryuichi; Peterson, Byron J.; Drapiko, Evgeny A.
  • Plasma and Fusion Research, Vol. 7, Issue 0
  • DOI: 10.1585/pfr.7.2405039

Calibration of a thin metal foil for infrared imaging video bolometer to estimate the spatial variation of thermal diffusivity using a photo-thermal technique
journal, May 2014

  • Pandya, Shwetang N.; Peterson, Byron J.; Sano, Ryuichi
  • Review of Scientific Instruments, Vol. 85, Issue 5
  • DOI: 10.1063/1.4873713

Research and Development of Imaging Bolometers
journal, January 2007

  • Peterson, Byron J.; Konoshima, Shigeru; Kostryukov, Artem Yu.
  • Plasma and Fusion Research, Vol. 2
  • DOI: 10.1585/pfr.2.S1018

Bolometric imaging of detached plasmas in LHD
journal, August 2011


Simulation of the Edge Plasma in Tokamaks
journal, January 2004


The EIRENE and B2-EIRENE Codes
journal, February 2005

  • Reiter, D.; Baelmans, M.; Börner, P.
  • Fusion Science and Technology, Vol. 47, Issue 2
  • DOI: 10.13182/FST47-172

In situ calibration of an infrared imaging video bolometer in the Large Helical Device
journal, November 2014

  • Mukai, K.; Peterson, B. J.; Pandya, S. N.
  • Review of Scientific Instruments, Vol. 85, Issue 11
  • DOI: 10.1063/1.4896959

Progress toward commissioning and plasma operation in NSTX-U
journal, June 2015


3D Edge Modeling and Island Divertor Physics
journal, April 2004

  • Feng, Y.; Sardei, F.; Kisslinger, J.
  • Contributions to Plasma Physics, Vol. 44, Issue 13
  • DOI: 10.1002/ctpp.200410009

Works referencing / citing this record:

Signal to noise ratio of upgraded imaging bolometer for KSTAR
journal, October 2018

  • Peterson, Byron J.; Oh, Seungtae; Seo, Dongcheol
  • Review of Scientific Instruments, Vol. 89, Issue 10
  • DOI: 10.1063/1.5038935