Preliminary design of a tangentially viewing imaging bolometer for NSTX-U

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.4955278· OSTI ID:22596563
 [1];  [2];  [3]; ; ; ;  [4]; ;  [5];  [6]
  1. National Institute for Fusion Science, Toki 509-5292 (Japan)
  2. The Graduate University for Advance Studies; Japan
  3. National Institutes for Quantum and Radiological Science and Technology, Naka, Ibaraki 311-0193 (Japan)
  4. Oak Ridge National Laboratory, Oak Ridge, Tennessee 37831 (United States)
  5. Princeton Plasma Physics Laboratory, Princeton, New Jersey 08543 (United States)
  6. FOM Institute DIFFER, 5612 AJ Eindhoven (Netherlands)

The infrared imaging video bolometer (IRVB) measures plasma radiated power images using a thin metal foil. Two different designs with a tangential view of NSTX-U are made assuming a 640 × 480 (1280 × 1024) pixel, 30 (105) fps, 50 (20) mK, IR camera imaging the 9 cm × 9 cm × 2 μm Pt foil. The foil is divided into 40 × 40 (64 × 64) IRVB channels. This gives a spatial resolution of 3.4 (2.2) cm on the machine mid-plane. The noise equivalent power density of the IRVB is given as 113 (46) μW/cm{sup 2} for a time resolution of 33 (20) ms. Synthetic images derived from Scrape Off Layer Plasma Simulation data using the IRVB geometry show peak signal levels ranging from ∼0.8 to ∼80 (∼0.36 to ∼26) mW/cm{sup 2}.

OSTI ID:
22596563
Journal Information:
Review of Scientific Instruments, Journal Name: Review of Scientific Instruments Journal Issue: 11 Vol. 87; ISSN 0034-6748; ISSN RSINAK
Country of Publication:
United States
Language:
English

Cited By (1)

Signal to noise ratio of upgraded imaging bolometer for KSTAR journal October 2018

Similar Records

Preliminary design of a tangentially viewing imaging bolometer for NSTX-U
Journal Article · Wed Aug 03 00:00:00 EDT 2016 · Review of Scientific Instruments · OSTI ID:1368172

Design and characterization of a prototype divertor viewing infrared video bolometer for NSTX-U
Journal Article · Mon Nov 14 23:00:00 EST 2016 · Review of Scientific Instruments · OSTI ID:22596633

Design and characterization of a prototype divertor viewing infrared video bolometer for NSTX-U
Journal Article · Tue Jul 12 00:00:00 EDT 2016 · Review of Scientific Instruments · OSTI ID:1368686