DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Continuous scanning mode for ptychography

Abstract

We outline how ptychographic imaging can be performed without the need for discrete scan positions. Through an idealized experiment, we demonstrate how a discrete-position scan regime can be replaced with a continuously scanned one with suitable modification of the reconstruction scheme based on coherent modes. Thus, the impact of this is that acquisition times can be reduced, significantly aiding ptychographic imaging with x rays, electrons, or visible light.

Authors:
 [1];  [2];  [3];  [4]
  1. Univ. of College London, London (United Kingdom)
  2. Brookhaven National Lab. (BNL), Upton, NY (United States)
  3. Argonne National Lab. (ANL), Argonne, IL (United States)
  4. Univ. of College London, London (United Kingdom); Research Complex at Harwell, Oxfordshire (United Kingdom)
Publication Date:
Research Org.:
Brookhaven National Laboratory (BNL), Upton, NY (United States); Argonne National Laboratory (ANL), Argonne, IL (United States). Advanced Photon Source (APS); SLAC National Accelerator Laboratory (SLAC), Menlo Park, CA (United States)
Sponsoring Org.:
USDOE Office of Science (SC), Basic Energy Sciences (BES)
OSTI Identifier:
1165962
Alternate Identifier(s):
OSTI ID: 1215662; OSTI ID: 1215664; OSTI ID: 1222361
Report Number(s):
BNL-107189-2014-JA
Journal ID: ISSN 0146-9592; OPLEDP; R&D Project: LS001
Grant/Contract Number:  
AC02-98CH10886; AC02-06CH11357; AC-02-98CH10886
Resource Type:
Accepted Manuscript
Journal Name:
Optics Letters
Additional Journal Information:
Journal Volume: 39; Journal Issue: 20; Journal ID: ISSN 0146-9592
Publisher:
Optical Society of America (OSA)
Country of Publication:
United States
Language:
English
Subject:
36 MATERIALS SCIENCE; microscopy; phase retrieval; scanning microscopy; X-ray microscopy

Citation Formats

Clark, Jesse N., Huang, Xiaojing, Harder, Ross J., and Robinson, Ian K. Continuous scanning mode for ptychography. United States: N. p., 2014. Web. doi:10.1364/OL.39.006066.
Clark, Jesse N., Huang, Xiaojing, Harder, Ross J., & Robinson, Ian K. Continuous scanning mode for ptychography. United States. https://doi.org/10.1364/OL.39.006066
Clark, Jesse N., Huang, Xiaojing, Harder, Ross J., and Robinson, Ian K. Wed . "Continuous scanning mode for ptychography". United States. https://doi.org/10.1364/OL.39.006066. https://www.osti.gov/servlets/purl/1165962.
@article{osti_1165962,
title = {Continuous scanning mode for ptychography},
author = {Clark, Jesse N. and Huang, Xiaojing and Harder, Ross J. and Robinson, Ian K.},
abstractNote = {We outline how ptychographic imaging can be performed without the need for discrete scan positions. Through an idealized experiment, we demonstrate how a discrete-position scan regime can be replaced with a continuously scanned one with suitable modification of the reconstruction scheme based on coherent modes. Thus, the impact of this is that acquisition times can be reduced, significantly aiding ptychographic imaging with x rays, electrons, or visible light.},
doi = {10.1364/OL.39.006066},
journal = {Optics Letters},
number = 20,
volume = 39,
place = {United States},
year = {Wed Oct 15 00:00:00 EDT 2014},
month = {Wed Oct 15 00:00:00 EDT 2014}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 46 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Phase retrieval with transverse translation diversity: a nonlinear optimization approach
journal, January 2008

  • Guizar-Sicairos, Manuel; Fienup, James R.
  • Optics Express, Vol. 16, Issue 10
  • DOI: 10.1364/OE.16.007264

Reconstructing state mixtures from diffraction measurements
journal, February 2013


Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing
journal, August 2013

  • Wilke, R. N.; Vassholz, M.; Salditt, T.
  • Acta Crystallographica Section A Foundations of Crystallography, Vol. 69, Issue 5
  • DOI: 10.1107/S0108767313019612

Ptychographic transmission microscopy in three dimensions using a multi-slice approach
journal, January 2012

  • Maiden, A. M.; Humphry, M. J.; Rodenburg, J. M.
  • Journal of the Optical Society of America A, Vol. 29, Issue 8
  • DOI: 10.1364/JOSAA.29.001606

Timepix, a 65k programmable pixel readout chip for arrival time, energy and/or photon counting measurements
journal, October 2007

  • Llopart, X.; Ballabriga, R.; Campbell, M.
  • Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, Vol. 581, Issue 1-2
  • DOI: 10.1016/j.nima.2007.08.079

Extracting coherent modes from partially coherent wavefields
journal, January 2009

  • Flewett, Samuel; Quiney, Harry M.; Tran, Chanh Q.
  • Optics Letters, Vol. 34, Issue 14
  • DOI: 10.1364/OL.34.002198

New theory of partial coherence in the space–frequency domain Part I: spectra and cross spectra of steady-state sources
journal, January 1982


Ptychographic electron microscopy using high-angle dark-field scattering for sub-nanometre resolution imaging
journal, January 2012

  • Humphry, M. J.; Kraus, B.; Hurst, A. C.
  • Nature Communications, Vol. 3, Issue 1
  • DOI: 10.1038/ncomms1733

Atom-Scale Ptychographic Electron Diffractive Imaging of Boron Nitride Cones
journal, February 2012


X-Ray Interactions: Photoabsorption, Scattering, Transmission, and Reflection at E = 50-30,000 eV, Z = 1-92
journal, July 1993

  • Henke, B. L.; Gullikson, E. M.; Davis, J. C.
  • Atomic Data and Nuclear Data Tables, Vol. 54, Issue 2, p. 181-342
  • DOI: 10.1006/adnd.1993.1013

Transmission microscopy without lenses for objects of unlimited size
journal, February 2007


High-throughput ptychography using Eiger-scanning X-ray nano-imaging of extended regions
journal, January 2014

  • Guizar-Sicairos, Manuel; Johnson, Ian; Diaz, Ana
  • Optics Express, Vol. 22, Issue 12
  • DOI: 10.1364/OE.22.014859

Quantitative Nanoscale Imaging of Lattice Distortions in Epitaxial Semiconductor Heterostructures Using Nanofocused X-ray Bragg Projection Ptychography
journal, September 2012

  • Hruszkewycz, S. O.; Holt, M. V.; Murray, C. E.
  • Nano Letters, Vol. 12, Issue 10
  • DOI: 10.1021/nl303201w

Formation of Optical Images by X-Rays
journal, January 1948

  • Kirkpatrick, Paul; Baez, A. V.
  • Journal of the Optical Society of America, Vol. 38, Issue 9
  • DOI: 10.1364/JOSA.38.000766

High-resolution ab initio three-dimensional x-ray diffraction microscopy
journal, January 2006

  • Chapman, Henry N.; Barty, Anton; Marchesini, Stefano
  • Journal of the Optical Society of America A, Vol. 23, Issue 5
  • DOI: 10.1364/JOSAA.23.001179

Dynamische Theorie der Kristallstrukturanalyse durch Elektronenbeugung im inhomogenen Primärstrahlwellenfeld
journal, November 1970

  • Hegerl, R.; Hoppe, W.
  • Berichte der Bunsengesellschaft für physikalische Chemie, Vol. 74, Issue 11
  • DOI: 10.1002/bbpc.19700741112

Sampling in x-ray ptychography
journal, May 2013


High-Resolution Scanning X-ray Diffraction Microscopy
journal, July 2008


Ptychographic X-ray computed tomography at the nanoscale
journal, September 2010

  • Dierolf, Martin; Menzel, Andreas; Thibault, Pierre
  • Nature, Vol. 467, Issue 7314
  • DOI: 10.1038/nature09419

Dynamic Imaging Using Ptychography
journal, March 2014


Hard-X-Ray Lensless Imaging of Extended Objects
journal, January 2007


Dynamic sample imaging in coherent diffractive imaging
journal, January 2011

  • Clark, Jesse N.; Putkunz, Corey T.; Curwood, Evan K.
  • Optics Letters, Vol. 36, Issue 11
  • DOI: 10.1364/OL.36.001954

Quantitative biological imaging by ptychographic x-ray diffraction microscopy
journal, December 2009

  • Giewekemeyer, K.; Thibault, P.; Kalbfleisch, S.
  • Proceedings of the National Academy of Sciences, Vol. 107, Issue 2
  • DOI: 10.1073/pnas.0905846107

Towards a Strategy for Automatic Phase Retrieval from Noisy Fourier Intensities
journal, May 1989


Ptychography with broad-bandwidth radiation
journal, April 2014

  • Enders, B.; Dierolf, M.; Cloetens, P.
  • Applied Physics Letters, Vol. 104, Issue 17
  • DOI: 10.1063/1.4874304

Semi-transparent central stop in high-resolution X-ray ptychography using Kirkpatrick–Baez focusing
text, January 2013

  • Wilke, R. N.; Vassholz, M.; Salditt, T.
  • Deutsches Elektronen-Synchrotron, DESY, Hamburg
  • DOI: 10.3204/desy-2014-01059

Works referencing / citing this record:

X-ray Microscopy
book, January 2019


X-ray ptychographic and fluorescence microscopy of frozen-hydrated cells using continuous scanning
journal, March 2017


Multimodal X-ray imaging of nanocontainer-treated macrophages and calcium distribution in the perilacunar bone matrix
journal, February 2020


Fly-scan ptychography
journal, March 2015

  • Huang, Xiaojing; Lauer, Kenneth; Clark, Jesse N.
  • Scientific Reports, Vol. 5, Issue 1
  • DOI: 10.1038/srep09074

On-the-fly scans for X-ray ptychography
journal, December 2014

  • Pelz, Philipp M.; Guizar-Sicairos, Manuel; Thibault, Pierre
  • Applied Physics Letters, Vol. 105, Issue 25
  • DOI: 10.1063/1.4904943

Multimodal hard x-ray imaging with resolution approaching 10 nm for studies in material science
journal, March 2018


Ptychographic imaging of NaD1 induced yeast cell death
journal, January 2019

  • Anthony, Nicholas; Darmanin, Connie; Bleackley, Mark R.
  • Biomedical Optics Express, Vol. 10, Issue 10
  • DOI: 10.1364/boe.10.004964

Correction of axial position uncertainty and systematic detector errors in ptychographic diffraction imaging
text, January 2018

  • Loetgering, Lars; Rose, Max; Keskinbora, Kahraman
  • Deutsches Elektronen-Synchrotron, DESY, Hamburg
  • DOI: 10.3204/pubdb-2019-00321

Correction of axial position uncertainty and systematic detector errors in ptychographic diffraction imaging
journal, August 2018

  • Loetgering, Lars; Rose, Max; Keskinbora, Kahraman
  • Optical Engineering, Vol. 57, Issue 08
  • DOI: 10.1117/1.oe.57.8.084106

X-ray microscopy
journal, July 1965