DOE PAGES title logo U.S. Department of Energy
Office of Scientific and Technical Information
  1. The Atacama Cosmology Telescope: DR6 power spectra, likelihoods and ΛCDM parameters

    We present power spectra of the cosmic microwave background (CMB) anisotropy in temperature and polarization, measured from the Data Release 6 maps made from Atacama Cosmology Telescope (ACT) data. These cover 19,000 deg2 of sky in bands centered at 98, 150 and 220 GHz, with white noise levels three times lower than Planck in polarization. We find that the ACT angular power spectra estimated over 10,000 deg2, and measured to arcminute scales in TT, TE and EE, are well fit by the sum of CMB and foregrounds, where the CMB spectra are described by the ΛCDM model. Combining ACT withmore » larger-scale Planck data, the joint P-ACT dataset provides tight limits on the ingredients, expansion rate, and initial conditions of the universe. We find similar constraining power, and consistent results, from either the Planck power spectra or from ACT combined with WMAP data, as well as from either temperature or polarization in the joint P-ACT dataset. When combined with CMB lensing from ACT and Planck, and baryon acoustic oscillation data from the Dark Energy Spectroscopic Instrument (DESI DR1), we measure a baryon density of Ωbh2 = 0.0226 ± 0.0001, a cold dark matter density of Ωch2 = 0.118 ± 0.001, a Hubble constant of H0 = 68.22 ± 0.36 km/s/Mpc, a spectral index of ns = 0.974 ± 0.003, and an amplitude of density fluctuations of σ8 = 0.813 ± 0.005. Including the DESI DR2 data tightens the Hubble constant to H0 = 68.43 ± 0.27 km/s/Mpc; ΛCDM parameters agree between the P-ACT and DESI DR2 data at the 1.6σ level. We find no evidence for excess lensing in the power spectrum, and no departure from spatial flatness. The contribution from Sunyaev-Zel'dovich (SZ) anisotropy is detected at high significance; we find evidence for a tilt with suppressed small-scale power compared to our baseline SZ template spectrum, consistent with hydrodynamical simulations with feedback.« less
  2. The Atacama Cosmology Telescope: DR6 constraints on extended cosmological models

    We use new cosmic microwave background (CMB) primary temperature and polarization anisotropy measurements from the Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) to test foundational assumptions of the standard cosmological model, ΛCDM, and set constraints on extensions to it. We derive constraints from the ACT DR6 power spectra alone, as well as in combination with legacy data from the Planck mission. To break geometric degeneracies, we include ACT and Planck CMB lensing data and baryon acoustic oscillation data from DESI Year-1. To test the dependence of our results on non-ACT data, we also explore combinations replacing Planck with WMAPmore » and DESI with BOSS, and further add supernovae measurements from Pantheon+ for models that affect the late-time expansion history. We verify the near-scale-invariance (running of the spectral index dns/d ln k = 0.0062 ± 0.0052) and adiabaticity of the primordial perturbations. Neutrino properties are consistent with Standard Model predictions: we find no evidence for new light, relativistic species that are free-streaming (Neff = 2.86 ± 0.13, which combined with astrophysical measurements of primordial helium and deuterium abundances becomes Neff = 2.89 ± 0.11), for non-zero neutrino masses (∑mν < 0.089 eV at 95% CL), or for neutrino self-interactions. We also find no evidence for self-interacting dark radiation (Nidr < 0.134), or for early-universe variation of fundamental constants, including the fine-structure constant (αEMEM,0 = 1.0043 ± 0.0017) and the electron mass (me/me,0 = 1.0063 ± 0.0056). Our data are consistent with standard big bang nucleosynthesis (we find Yp = 0.2312 ± 0.0092), the COBE/FIRAS-inferred CMB temperature (we find TCMB = 2.698 ± 0.016 K), a dark matter component that is collisionless and with only a small fraction allowed as axion-like particles, a cosmological constant (w = -0.986 ± 0.025), and the late-time growth rate predicted by general relativity (γ = 0.663 ± 0.052). We find no statistically significant preference for a departure from the baseline ΛCDM model. In fits to models invoking early dark energy, primordial magnetic fields, or an arbitrary modified recombination history, we find H0 = 69.9+0.8-1.5, 69.1 ± 0.5, or 69.6 ± 1.0 km/s/Mpc, respectively; using BOSS instead of DESI BAO data reduces the central values of these constraints by 1–1.5 km/s/Mpc while only slightly increasing the error bars. In general, models introduced to increase the Hubble constant or to decrease the amplitude of density fluctuations inferred from the primary CMB are not favored over ΛCDM by our data.« less
  3. The Atacama Cosmology Telescope: DR6 maps

    We present Atacama Cosmology Telescope (ACT) Data Release 6 (DR6) maps of the Cosmic Microwave Background temperature and polarization anisotropy at arcminute resolution over three frequency bands centered on 98, 150 and 220 GHz. The maps are based on data collected with the AdvancedACT camera over the period 2017–2022 and cover 19,000 square degrees with a median combined depth of 10 μK arcmin. We describe the instrument, mapmaking and map properties and illustrate them with a number of figures and tables.
  4. Noise limits for dc SQUID readout of high-Q resonators below 300 MHz

    We present the limits on noise for the readout of cryogenic high-Q resonators using dc Superconducting Quantum Interference Devices (SQUIDs) below 300 MHz. This analysis uses realized first-stage SQUIDs (previously published), whose performance is well described by Tesche–Clarke (TC) theory, coupled directly to the resonators. We also present data from a prototype second-stage dc SQUID array designed to couple to this first-stage SQUID as a follow-on amplifier with high system bandwidth. This analysis is the first full consideration of dc SQUID noise performance referred to a high-Q resonator over this frequency range and is presented relative to the standard quantummore » limit. We include imprecision, backaction, and backaction–imprecision noise correlations from TC theory, the noise contributed by the second-stage SQUIDs, wiring, and preamplifiers, and optimizations for both on-resonance measurements and off-resonance scan sensitivity. This architecture has modern relevance due to the increased interest in axion searches and the requirements of the DMRadio-m3 axion search, which uses dc SQUIDs in this frequency range.« less
  5. Electromagnetic modeling and science reach of DMRadio-m3

    DMRadio-m3 is an experimental search for dark matter axions. It uses a solenoidal dc magnetic field to convert an axion dark-matter signal to an ac electromagnetic response in a coaxial copper pickup. The current induced by this axion signal is measured by dc SQUIDs. DMRadio-m3 is designed to be sensitive to Kim-Shifman-Vainshtein-Zakharov (KSVZ) and Dine-Fischler-Srednicki-Zhitnisky (DFSZ) QCD axion models in the 10–200 MHz (41 neV/𝑐2–0.83 μ⁢eV/𝑐2) range, and to axions with 𝑔𝑎⁢𝛾⁢𝛾 =𝑔𝑎⁢𝛾⁢𝛾,DFSZ⁡(30 MHz) =1.87 ×10−17 GeV−1 over 5–30 MHz as an extended goal. In this work, we present the electromagnetic modeling of the response of the experiment to anmore » axion signal over the full frequency range of DMRadio-m3, which extends from the low-frequency, lumped-element limit to a regime where the axion Compton wavelength is only a factor of 2 larger than the detector size. With these results, we determine the live time and sensitivity of the experiment. The primary science goal of sensitivity to DFSZ axions across 30–200 MHz can be achieved with a 3⁢𝜎 live scan time of 2.9 years.« less
  6. Measurements of DC SQUID Damping Effects on Superconducting Resonant Circuits

    Here, we present experimental measurements of SQUID-induced damping effects on strongly coupled, lumped-element resonators in the 500kHz–1 MHz frequency range. While dc SQUIDs are commonly used for sensitive readout of electromagnetic signals such as in lumped-element axion dark matter searches, coupling a dc SQUID to a resonant circuit modifies the circuit's resonance frequency, quality factor, noise, and impedance. These parameters have a direct impact on the science reach of axion dark matter detectors, making it important to understand SQUID damping contributions. We describe a helium dip probe and two-stage SQUID readout scheme used to probe SQUID damping effects. Measurements frommore » this setup inform the design and operation of both future test platforms as well as next-generation dark-matter experiments.« less

Search for:
All Records
Creator / Author
0000000239212313

Refine by:
Article Type
Availability
Journal
Creator / Author
Publication Date
Research Organization