Microdosimetric TLD measurements for tumor associated antibody therapy
Conference
·
· J. Nucl. Med.; (United States)
OSTI ID:6403462
Currently, radiation dose in experimental tumored animals undergoing radioimmunotherapy trials is computed indirectly by assessing serial time-dependent biodistribution data, mean residence times and cumulated activities. These data are then used to calculate organ doses through the standard MIRD formalism. Substantial uncertainty in the absorbed organ doses are a result of model dependent assumptions regarding geometrical and radiation attenuation factors for heterogeneous tissue equivalent medium. The authors have developed a method for the direct verification of absorbed radiation dose through the use of teflon-imbedded, Teledyne CaSO/sub 4/:Dy thermoluminescent dosimeters (TLD) which have been modified to fit inside a 20 gauge needle. Typical TLD dimensions are in a rod-shape configuration of 0.2 x 0.5 x 5mm.
- Research Organization:
- George Washington Univ., Washington, DC
- OSTI ID:
- 6403462
- Report Number(s):
- CONF-840619-
- Conference Information:
- Journal Name: J. Nucl. Med.; (United States) Journal Volume: 25:5
- Country of Publication:
- United States
- Language:
- English
Similar Records
Miniature thermoluminescent dosimeter absorbed dose measurements in tumor phantom models
Mini-TL-Dosimeters for in vivo measurements
CaSO sub 4 :Dy environmental TLD performance testing
Journal Article
·
Fri Aug 01 00:00:00 EDT 1986
· J. Nucl. Med.; (United States)
·
OSTI ID:5014431
Mini-TL-Dosimeters for in vivo measurements
Journal Article
·
Sun May 01 00:00:00 EDT 1994
· Journal of Nuclear Medicine
·
OSTI ID:197951
CaSO sub 4 :Dy environmental TLD performance testing
Journal Article
·
Wed Jan 31 23:00:00 EST 1990
· Radiation Protection Management; (United States)
·
OSTI ID:5227256
Related Subjects
550604* -- Medicine-- Unsealed Radionuclides in Therapy-- (1980-)
560152 -- Radiation Effects on Animals-- Animals
62 RADIOLOGY AND NUCLEAR MEDICINE
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
ANIMALS
ANTIBODIES
CALIBRATION
DATA ANALYSIS
DESIGN
DISEASES
DISTRIBUTION
DOSEMETERS
DOSES
DOSIMETRY
DRUGS
IMMUNOLOGY
IMPLANTS
LABELLED COMPOUNDS
LUMINESCENT DOSEMETERS
MAMMALS
MEASURING INSTRUMENTS
MEDICINE
MELANOMAS
MICE
MICRODOSIMETRY
MODIFICATIONS
MONOCLONAL ANTIBODIES
NEOPLASMS
NUCLEAR MEDICINE
PERFORMANCE
RADIATION DOSES
RADIOIMMUNOLOGY
RADIOIMMUNOTHERAPY
RADIOLOGY
RADIOPHARMACEUTICALS
RADIOTHERAPY
RODENTS
THERAPY
THERMOLUMINESCENT DOSEMETERS
THERMOLUMINESCENT DOSIMETRY
TISSUE DISTRIBUTION
VERTEBRATES
560152 -- Radiation Effects on Animals-- Animals
62 RADIOLOGY AND NUCLEAR MEDICINE
63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTANT EFFECTS ON LIVING ORGS. AND BIOL. MAT.
ANIMALS
ANTIBODIES
CALIBRATION
DATA ANALYSIS
DESIGN
DISEASES
DISTRIBUTION
DOSEMETERS
DOSES
DOSIMETRY
DRUGS
IMMUNOLOGY
IMPLANTS
LABELLED COMPOUNDS
LUMINESCENT DOSEMETERS
MAMMALS
MEASURING INSTRUMENTS
MEDICINE
MELANOMAS
MICE
MICRODOSIMETRY
MODIFICATIONS
MONOCLONAL ANTIBODIES
NEOPLASMS
NUCLEAR MEDICINE
PERFORMANCE
RADIATION DOSES
RADIOIMMUNOLOGY
RADIOIMMUNOTHERAPY
RADIOLOGY
RADIOPHARMACEUTICALS
RADIOTHERAPY
RODENTS
THERAPY
THERMOLUMINESCENT DOSEMETERS
THERMOLUMINESCENT DOSIMETRY
TISSUE DISTRIBUTION
VERTEBRATES