Radioimmunoassay T-2 toxin in biological fluids

Conference · · J. Assoc. Off. Anal. Chem.; (United States)
OSTI ID:5926136
A simple radioimmunoassay (RIA) for detection of T-2 toxin in biological fluids was developed. The method, which involves a Sep-Pak C/sub 18/ reverse phase column cleanup step before RIA, can detect 0.5 ppb T-2 toxin in serum and 2.5 ppb T-2 toxin in urine and milk. Recoveries for toxin added to serum and urine or milk samples were 87-106% in the 0.5-20 ppb range and 88-117% in the 2.5-20 ppb range, respectively. If samples were not cleaned up, false positive results prevented positive detection at concentrations less than 2.5 ppb in urine and milk.
Research Organization:
Univ. of Wisconsin, Madison
OSTI ID:
5926136
Conference Information:
Journal Name: J. Assoc. Off. Anal. Chem.; (United States) Journal Volume: 64:3
Country of Publication:
United States
Language:
English