Irradiation tests of various plasticizers for polyvinyl chloride which satisfy requirements for use in gasket or oil seal material are described. Of the materials tested, Reoplex polymeric plasticizers, dioctyl phthalate, dioctyl sebacate, and tritolyl phosphate, the latter resulted in polyinyl chloride far less affected by gamma radiation of 10/sup 7/ to 10/sup 8/ r than the others. The Reoplexes were second best, the others being poor. The plasticizers constituted 40 wt. % of the test material. (T.R.H.)