Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

RADIATION AND TEMPERATURE TESTS OF MINIATURE TRANSISTOR AMPLIFIERS

Technical Report ·
OSTI ID:4271630
The results of radiation and temperature tests run on two different types of miniature transistor amplifiers are presented. Performance curves are shown, and an analysis of the results leading to a possible method of failure prediction is given. One of the amplifier types was successfully tested to a temperature of 150 C, gamma irradiation of 4.7 x 10/sup 7/ roentgens, and a fast neutron dosage of 7.0 x 10/sup 13/ nvt (epicadmium). These results place the use of such an amplifier within the realm of feasibility as an airframe- mounted control component. (auth)
Research Organization:
General Electric Co. Aircraft Nuclear Propulsion Dept., Cincinnati
DOE Contract Number:
AT(11-1)-171
NSA Number:
NSA-13-012162
OSTI ID:
4271630
Report Number(s):
APEX-477
Country of Publication:
United States
Language:
English

Similar Records

RADIATION AND TEMPERATURE TESTS OF MINIATURE TRANSISTOR AMPLIFIERS
Technical Report · Wed Nov 19 23:00:00 EST 1958 · OSTI ID:4819028

RADIATION AND TEMPERATURE TESTS OF MINIATURE TRANSISTOR AMPLIFIERS
Journal Article · Mon Jun 01 00:00:00 EDT 1959 · Nuclear Sci. and Eng. · OSTI ID:4243829

A REPORT OF THE IN-PILE TESTING OF TWELVE BOURNS TRIMPOTS-CXI-42
Technical Report · Tue Nov 10 23:00:00 EST 1959 · OSTI ID:4802268