Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

RADIATION AND TEMPERATURE TESTS OF MINIATURE TRANSISTOR AMPLIFIERS

Journal Article · · Nuclear Sci. and Eng.
OSTI ID:4243829

In the application of transistorized reactor control cireuitry to airborne nuclear systems, two factors of particular interest are the effects of radiation and high temperatures. The results of radiation and temperature tests run on two different types of miniature transistor feedback amplifiers are presented. One of the amplifier types was successfully tested to a temperature of 150 deg C, a gamma irradiation of 4.7 x 10/sup 7/r, and a fast neutron dosage of 7.0 x 10/sup 13/ nvt. (W.D.M.)

Research Organization:
General Electric Co., Cincinnati
NSA Number:
NSA-13-017480
OSTI ID:
4243829
Journal Information:
Nuclear Sci. and Eng., Journal Name: Nuclear Sci. and Eng. Vol. Vol: 2, No. 1, Suppl.
Country of Publication:
Country unknown/Code not available
Language:
English