PERIODIC PRIMARY PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results T- 641102. First issue, June 14, 1961
Tests performed on the Shippingport PWR to determine the magnitude and sources of primary coolant water leakage from the reactor coolant system are described. Two of the pressurizer relief valves are found to account for 80% of the total leaksge of 56 gal/hr from six pressure rehief and reactor relief valves. Other valves are found to have insignificant leakage. The total primary coolant water leakage is found to be 26 gal/hr. (auth)
- Research Organization:
- Duquesne Light Co., Shippingport, Penna.
- NSA Number:
- NSA-15-025627
- OSTI ID:
- 4014031
- Report Number(s):
- DLCS-2110140
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results T- 641102. First Issue, JUNE 14, 1961
PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results
PERIODIC PRIMARY PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Evaluation T- 641102
Technical Report
·
Mon Oct 30 23:00:00 EST 1961
·
OSTI ID:4014030
PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results
Technical Report
·
Thu Jan 19 23:00:00 EST 1961
·
OSTI ID:4027929
PERIODIC PRIMARY PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Evaluation T- 641102
Technical Report
·
Wed Jun 14 00:00:00 EDT 1961
·
OSTI ID:4841169