PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results

Technical Report ·
DOI:https://doi.org/10.2172/4027929· OSTI ID:4027929
An investigation was made to determine the magnitude and location of the reactor coolant system leakage of the Shippingport Power Beactor. The "total" plant leakage was indicated by the pressurizer level change since no make-up was added during the test. The "accounted for" leakage was indicated by the flash tank level change and the blowoff tank level change. The relief valves from the pressurizer and reactor were checked for leakage individrually and a combined leakage of 2.84 gal/hr was obtainsd for the 6 valves tested. The system was found to have a total leak rate of 5.65 gal/hr of which 1.17 gal/hr was "accounted for." (M.C.G.)
Research Organization:
Duquesne Light Co., Shippingport, Penna.
NSA Number:
NSA-15-016689
OSTI ID:
4027929
Report Number(s):
DLCS-2110132
Country of Publication:
Country unknown/Code not available
Language:
English