PERIODIC REACTOR PLANT LEAK RATE TEST. CORE 1, SEED 2. Test Results T- 641102. First Issue, JUNE 14, 1961
Tests were performed on the Shippingport PWR to determine the magnitude and location of coolant system leakages. The total leakage from pressurizer relief and reactor relief valves was 62.1 gal/hr. The total plant leakage was 19.3 gal/hr. (T.F.H.)