An important issue for resists used in soft x-ray projection lithography (SXPL) is high absorption. Absorption coefficients of both organic and inorganic formulations range from 2--6 {mu}m{sup {minus}1}, requiring the use of very thin (50--100 nm) layers to avoid excessive absorption and resulting pattern sidewall degradation. Such thin films are typically used as the imaging layer in a bi- or tri-level processing scheme to achieve the required pattern depth. In this work, we report experimental and theoretical studies of imaging performance in the resists PMMA and SAL 601 at an SXPL exposure wavelength of 13.9 nm. Absorption coefficients (({alpha}) have been measured for, and SXPL images recorded in both of these resists. A Mo/Si multilayer-coated Schwarzschild objective having known aberrations and illuminated by a laser plasma soft x-ray source has been used to produce images. Calculated aberrated aerial images are used in conjunction with the measured values of ({alpha} to model the expected resist profiles and these are compared to experiment. Imaging performance as a function of resist absorption and estimates of resist exposure latitude are also discussed.
- Research Organization:
- Sandia National Labs., Albuquerque, NM (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); Department of Defense, Washington, DC (United States)
- DOE Contract Number:
- AC04-76DP00789
- OSTI ID:
- 10167332
- Report Number(s):
- SAND--93-8541C; CONF-9302130--1; ON: DE93016490
- Country of Publication:
- United States
- Language:
- English
Similar Records
Resist performance in soft x-ray projection lithography
Chemically amplified soft-x-ray resists: sensitivity, resolution, and molecular photodesorption
Wavelength dependence of the resist sidewall angle in extreme ultraviolet lithography
Conference
·
Thu Dec 31 23:00:00 EST 1992
·
OSTI ID:7368549
Chemically amplified soft-x-ray resists: sensitivity, resolution, and molecular photodesorption
Journal Article
·
Tue Nov 30 23:00:00 EST 1993
· Applied Optics; (United States)
·
OSTI ID:5340780
Wavelength dependence of the resist sidewall angle in extreme ultraviolet lithography
Journal Article
·
Mon Oct 31 23:00:00 EST 1994
· Journal of Vacuum Science and Technology. B, Microelectronics Processing and Phenomena; (United States)
·
OSTI ID:7094682