skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Measurements of a newly designed BPM for the Tevatron Electron Lens 2

Conference · · AIP Conf.Proc.868:481-487,2006
OSTI ID:892312

Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses ({approx}1 us) of up to {approx}1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new compact four plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsed with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency dependent transverse position offset may be reduced to {approx}0.1 mm for the beam structures of interest.

Research Organization:
Fermi National Accelerator Lab. (FNAL), Batavia, IL (United States)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76CH03000
OSTI ID:
892312
Report Number(s):
FERMILAB-CONF-06-140-AD; TRN: US0701362
Journal Information:
AIP Conf.Proc.868:481-487,2006, Conference: Presented at 12th Beam Instrumentation Workshop (BIW06), Fermilab, Batavia, Illinois, 1-4 May 2006
Country of Publication:
United States
Language:
English