Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measurements of a Newly Designed BPM for the Tevatron Electron Lens 2

Journal Article · · AIP Conference Proceedings
DOI:https://doi.org/10.1063/1.2401438· OSTI ID:20894950
; ; ; ; ; ; ;  [1]
  1. Fermi National Accelerator Laboratory, P.O. Box 500, Batavia, IL 60510 (United States)
Fermilab has developed a second electron lens (TEL-2) for beam-beam compensation in the Tevatron as part of its Run II upgrade program. Operation of the beam position monitors (BPMs) in the first electron lens (TEL-1) showed a systematic transverse position difference between short proton bunches (2 ns sigma) and long electron pulses ({approx}1 us) of up to {approx}1.5 mm. This difference was attributed to frequency dependence in the BPM system. The TEL-2 BPMs utilize a new, compact four-plate design with grounding strips between plates to minimize crosstalk. In-situ measurements of these new BPMs are made using a stretched wire pulsed with both proton and electron beam formats. In addition, longitudinal impedance measurements of the TEL-2 are presented. Signal processing algorithm studies indicate that the frequency-dependent transverse position offset may be reduced to {approx}0.1 mm for the beam structures of interest.
OSTI ID:
20894950
Journal Information:
AIP Conference Proceedings, Journal Name: AIP Conference Proceedings Journal Issue: 1 Vol. 868; ISSN APCPCS; ISSN 0094-243X
Country of Publication:
United States
Language:
English

Similar Records

Measurements of a newly designed BPM for the Tevatron Electron Lens 2
Conference · Mon May 01 00:00:00 EDT 2006 · AIP Conf.Proc.868:481-487,2006 · OSTI ID:892312

A 6 kV arbitrary waveform generator for the Tevatron Electron Lens
Journal Article · Tue Nov 08 23:00:00 EST 2011 · Journal of Instrumentation · OSTI ID:1030724

The special applications of Tevatron electron lens
Conference · Mon Aug 11 00:00:00 EDT 2003 · OSTI ID:812756