skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: NSLS-II BPM System Protection from Rogue Mode Coupling

Conference ·
OSTI ID:1012578

Rogue mode RF shielding has been successfully designed and implemented into the production multipole vacuum chambers. In order to avoid systematic errors in the NSLS-II BPM system we introduced frequency shift of HOM's by using RF metal shielding located in the antechamber slot of each multipole vacuum chamber. To satisfy the pumping requirement the face of the shielding has been perforated with roughly 50 percent transparency. It stays clear of synchrotron radiation in each chamber.

Research Organization:
Brookhaven National Lab. (BNL), Upton, NY (United States). National Synchrotron Light Source
Sponsoring Organization:
DOE - Office Of Science
DOE Contract Number:
DE-AC02-98CH10886
OSTI ID:
1012578
Report Number(s):
BNL-94856-2011-CP; 39KC0200; TRN: US1102320
Resource Relation:
Conference: PAC 2011; New York, NY; 20110328 through 20110328
Country of Publication:
United States
Language:
English