Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials
Abstract
Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.
- Authors:
-
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Publication Date:
- Research Org.:
- Los Alamos National Lab. (LANL), Los Alamos, NM (United States)
- Sponsoring Org.:
- USDOE National Nuclear Security Administration (NNSA), Office of Defense Programs (DP)
- OSTI Identifier:
- 1343715
- Alternate Identifier(s):
- OSTI ID: 1416754
- Report Number(s):
- LA-UR-16-26781
Journal ID: ISSN 0039-9140
- Grant/Contract Number:
- AC52-06NA25396
- Resource Type:
- Accepted Manuscript
- Journal Name:
- Talanta
- Additional Journal Information:
- Journal Volume: 167; Journal Issue: C; Journal ID: ISSN 0039-9140
- Publisher:
- Elsevier
- Country of Publication:
- United States
- Language:
- English
- Subject:
- 11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS; uranium, plutonium, quality, nuclear forensics, anion exchange, chromatography, spectroscopy, microchemistry; microfluidic device; trace impurity; plutonium; uranium; nuclear forensics
Citation Formats
Gao, Jun, Manard, Benjamin Thomas, Castro, Alonso, Montoya, Dennis Patrick, Xu, Ning, and Chamberlin, Rebecca M. Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials. United States: N. p., 2017.
Web. doi:10.1016/j.talanta.2017.01.080.
Gao, Jun, Manard, Benjamin Thomas, Castro, Alonso, Montoya, Dennis Patrick, Xu, Ning, & Chamberlin, Rebecca M. Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials. United States. https://doi.org/10.1016/j.talanta.2017.01.080
Gao, Jun, Manard, Benjamin Thomas, Castro, Alonso, Montoya, Dennis Patrick, Xu, Ning, and Chamberlin, Rebecca M. Thu .
"Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials". United States. https://doi.org/10.1016/j.talanta.2017.01.080. https://www.osti.gov/servlets/purl/1343715.
@article{osti_1343715,
title = {Solid-phase extraction microfluidic devices for matrix removal in trace element assay of actinide materials},
author = {Gao, Jun and Manard, Benjamin Thomas and Castro, Alonso and Montoya, Dennis Patrick and Xu, Ning and Chamberlin, Rebecca M.},
abstractNote = {Advances in sample nebulization and injection technology have significantly reduced the volume of solution required for trace impurity analysis in plutonium and uranium materials. Correspondingly, we have designed and tested a novel chip-based microfluidic platform, containing a 100-µL or 20-µL solid-phase microextraction column, packed by centrifugation, which supports nuclear material mass and solution volume reductions of 90% or more compared to standard methods. Quantitative recovery of 28 trace elements in uranium was demonstrated using a UTEVA chromatographic resin column, and trace element recovery from thorium (a surrogate for plutonium) was similarly demonstrated using anion exchange resin AG MP-1. Of nine materials tested, compatibility of polyvinyl chloride (PVC), polypropylene (PP), and polytetrafluoroethylene (PTFE) chips with the strong nitric acid media was highest. Finally, the microcolumns can be incorporated into a variety of devices and systems, and can be loaded with other solid-phase resins for trace element assay in high-purity metals.},
doi = {10.1016/j.talanta.2017.01.080},
journal = {Talanta},
number = C,
volume = 167,
place = {United States},
year = {Thu Feb 02 00:00:00 EST 2017},
month = {Thu Feb 02 00:00:00 EST 2017}
}
Web of Science
Works referenced in this record:
Quality control of (Th,Pu)O2 fuel pellet obtained by coated agglomerate pelletization
journal, August 2015
- Somayajulu, P. S.; Sengupta, Arijit; Karande, A. K.
- Journal of Radioanalytical and Nuclear Chemistry, Vol. 308, Issue 2
Determination of Trace and Ultratrace Elements in Uranium-Silicide (U3Si2) Fuel Employing Inductively Coupled Plasma Mass Spectrometry
journal, October 2014
- Nagar, B. K.; Deb, S. B.
- Atomic Spectroscopy, Vol. 35, Issue 5
The Determination of Impurities in Plutonium Metal by Anion Exchange and ICP/AES
journal, February 1989
- Huff, Edmund A.; Bowers, Delbert L.
- Applied Spectroscopy, Vol. 43, Issue 2
A brief introduction to analytical methods in nuclear forensics
journal, July 2012
- Stanley, Floyd E.; Stalcup, A. M.; Spitz, H. B.
- Journal of Radioanalytical and Nuclear Chemistry, Vol. 295, Issue 2
Interviewing a Silent (Radioactive) Witness through Nuclear Forensic Analysis
journal, September 2015
- Mayer, Klaus; Wallenius, Maria; Varga, Zsolt
- Analytical Chemistry, Vol. 87, Issue 23
Novel sample introduction system to reduce ICP-OES sample size for plutonium metal trace impurity determination
journal, December 2015
- Montoya, Dennis P.; Manard, Benjamin T.; Xu, Ning
- Journal of Radioanalytical and Nuclear Chemistry, Vol. 307, Issue 3
Liquid–liquid extraction of uranium(VI) with Aliquat® 336 from HCl media in microfluidic devices: Combination of micro-unit operations and online ICP-MS determination
journal, July 2015
- Hellé, Gwendolyne; Mariet, Clarisse; Cote, Gérard
- Talanta, Vol. 139
Evaluation of plutonium(IV) extraction rate between nitric acid and tri- n -butylphosphate solution using a glass chip microchannel: Other Techniques
journal, April 2015
- Yamamoto, Masahiko; Taguchi, Shigeo; Sato, Soichi
- Journal of Separation Science, Vol. 38, Issue 10
Microfluidic-Based Sample Chips for Radioactive Solutions
journal, March 2015
- Tripp, J. L.; Law, J. D.; Smith, T. E.
- Nuclear Technology, Vol. 189, Issue 3
Centrifugal microfluidic platform for radiochemistry: Potentialities for the chemical analysis of nuclear spent fuels
journal, November 2013
- Bruchet, Anthony; Taniga, Vélan; Descroix, Stéphanie
- Talanta, Vol. 116
Trace element analysis of high purity arsenic through vapour phase dissolution and ICP-QMS
journal, March 2003
- Balarama Krishna, M.
- Talanta, Vol. 59, Issue 3
Trace element profile of semiconductor materials: Gallium and arsenic
journal, August 1998
- Kayasth, Satish; Raje, Naina; Asari, T. P. S.
- Analytica Chimica Acta, Vol. 370, Issue 1
Determination of Trace Elements in High Purity Tungsten by Solid-Phase Extraction/ICP-MS
journal, January 2008
- Hasegawa, Shin-ichi
- MATERIALS TRANSACTIONS, Vol. 49, Issue 9
Rapid determination of 26 elements in iron meteorites using matrix removal and membrane desolvating quadrupole ICP-MS
journal, January 2014
- Duan, Xiaoxia; Regelous, Marcel
- J. Anal. At. Spectrom., Vol. 29, Issue 12
Elemental composition in sealed plutonium–beryllium neutron sources
journal, January 2015
- Xu, N.; Kuhn, K.; Gallimore, D.
- Applied Radiation and Isotopes, Vol. 95
The Influence of Crosslinkage on the Distribution Coefficients and Anion Exchange Behaviour of some Elements in Hydrochloric acid
journal, October 1985
- Walt, T. N. van der; Strelow, F. W. E.; Verheij, R.
- Solvent Extraction and Ion Exchange, Vol. 3, Issue 5
Separation and preconcentration of uranium from acidic media by extraction chromatography
journal, August 1992
- Horwitz, E. Philip; Dietz, Mark L.; Chiarizia, Renato
- Analytica Chimica Acta, Vol. 266, Issue 1
Works referencing / citing this record:
Analysis of Rare Earth Elements in Uranium Using Handheld Laser-Induced Breakdown Spectroscopy (HH LIBS)
journal, May 2018
- Manard, Benjamin T.; Wylie, E. Miller; Willson, Stephen P.
- Applied Spectroscopy, Vol. 72, Issue 11
Atomic spectrometry update: review of advances in the analysis of metals, chemicals and materials
journal, January 2018
- Carter, Simon; Clough, Robert; Fisher, Andy
- Journal of Analytical Atomic Spectrometry, Vol. 33, Issue 11
Rare Earth Element Determination in Uranium Ore Concentrates Using Online and Offline Chromatography Coupled to ICP-MS
journal, January 2020
- Bradley, Veronica C.; Manard, Benjamin T.; Roach, Benjamin D.
- Minerals, Vol. 10, Issue 1
Evaluation and Specifications for In-Line Uranium Separations Using Inductively Coupled Plasma Optical Emission Spectroscopy (ICP-OES) Detection for Trace Elemental Analysis
journal, March 2019
- Manard, Benjamin T.; Metzger, Shalina C.; Quarles, C. Derrick
- Applied Spectroscopy, Vol. 73, Issue 8
Atomic spectrometry update: review of advances in the analysis of metals, chemicals and materials
journal, January 2020
- Carter, Simon; Clough, Robert; Fisher, Andy
- Journal of Analytical Atomic Spectrometry, Vol. 35, Issue 11
Atomic spectrometry update. Review of advances in the analysis of metals, chemicals and materials
journal, January 2013
- Carter, Simon; Fisher, Andy S.; Hinds, Michael W.
- Journal of Analytical Atomic Spectrometry, Vol. 28, Issue 12
Atomic spectrometry update: review of advances in the analysis of metals, chemicals and materials
journal, January 2017
- Carter, Simon; Fisher, Andy; Gibson, Bridget
- Journal of Analytical Atomic Spectrometry, Vol. 32, Issue 11