Title: Microfluidic In-Situ Spectrophotometric Approaches to Tackle Actinides Analysis in Multiple Oxidation States

Journal Article · · Applied Spectroscopy

The study and development of present and future processes for the treatment/recycling of spent nuclear fuels require many steps, from design in the laboratory to setting up on an industrial scale. In all of these steps, analysis and instrumentation are key points. For scientific reasons (small-scale studies, control of phenomena, etc.) but also with regard to minimizing costs, risks, and waste, such developments are increasingly carried out on milli- or microfluidic devices. The logic is the same for the chemical analyses associated with their follow-up and interpretation. Due to this, over the last few years, opto–microfluidic analysis devices adapted to the monitoring of different processes (dissolution, liquid–liquid extraction, precipitation, etc.) have been increasingly designed and developed. In this work, we prove that photonic lab-on-a-chip (PhLoC) technology is fully suitable for all actinides concentration monitoring along the plutonium uranium refining extraction (plutonium, uranium, reduction, extraction, or Purex) process. Several PhLoC microfluidic platforms were specifically designed and used in different nuclear research and development (R&D) laboratories, to tackle actinides analysis in multiple oxidation states even in mixtures. The detection limits reached (tens of µmol·L −1 ) are fully compliant with on-line process monitoring, whereas a range of analyzable concentrations of three orders of magnitude can be covered with less than 150 µL of analyte. Finally, this work confirms the possibility and the potential of coupling Raman and ultraviolet–visible (UV–Vis) spectroscopies at the microfluidic scale, opening the perspective of measuring very complex mixtures.

Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (United States)
Sponsoring Organization:
USDOE
Grant/Contract Number:
AC05-76RL01830
OSTI ID:
1866842
Report Number(s):
PNNL-SA-164597
Journal Information:
Applied Spectroscopy, Journal Name: Applied Spectroscopy Journal Issue: 5 Vol. 76; ISSN 0003-7028
Publisher:
SAGE PublicationsCopyright Statement
Country of Publication:
United States
Language:
English

References (30)

Uranium(VI) speciation by spectroscopy journal October 1997
Electrochemical and spectroscopic studies of Pu(IV) and Pu(III) in nitric acid solutions journal May 2012
On-line monitoring of the U(VI) concentration in 30 vol.% TBP/kerosene: an evaluation of real-time analysis in polyetheretherketone (PEEK) containers via Raman spectroscopy journal March 2015
Photonic Lab-on-a-Chip analytical systems for nuclear applications: optical performance and UV–Vis–IR material characterization after chemical exposure and gamma irradiation journal December 2019
Molar absorptivities of U(VI), U(IV), and Pu(III) in nitric acid solutions of various concentrations relevant to developing nuclear fuel recycling flowsheets journal April 2020
Sequential determination of uranium (IV), free acidity and hydrazine in a single aliquot journal July 2010
Spectrophotometric determination of uranium and nitric acid by applying partial least-squares regression to uranium(VI) absorption spectra journal November 1991
Molecule-radiation and molecule-molecule processes in condensed media: a microscopic QED theory journal September 1995
Small but Perfectly Formed? Successes, Challenges, and Opportunities for Microfluidics in the Chemical and Biological Sciences journal February 2017
Determination of the lanthanides, uranium and plutonium by means of on-line high-pressure ion chromatography coupled with sector field inductively coupled plasma-mass spectrometry to characterize nuclear samples journal April 2020
Feasibility study of a microsystem to analyse radioactive solutions journal June 2007
Broadcasting photonic lab on a chip concept through a low cost manufacturing approach journal August 2017
Limit of detection. A closer look at the IUPAC definition journal June 1983
Water O–H Stretching Raman Signature for Strong Acid Monitoring via Multivariate Analysis journal March 2013
Enabling Microscale Processing: Combined Raman and Absorbance Spectroscopy for Microfluidic On-Line Monitoring journal December 2020
Raman Spectroscopy Coupled with Chemometric Analysis for Speciation and Quantitative Analysis of Aqueous Phosphoric Acid Systems journal March 2021
Photonic Lab-on-a-Chip: Integration of Optical Spectroscopy in Microfluidic Systems journal May 2016
Multivariate Analysis for Quantification of Plutonium(IV) in Nitric Acid Based on Absorption Spectra journal August 2017
Micro-Raman Technology to Interrogate Two-Phase Extraction on a Microfluidic Device journal May 2018
Uranium(VI) On-Chip Microliter Concentration Measurements in a Highly Extended UV–Visible Absorbance Linearity Range journal January 2018
Reimagining pH Measurement: Utilizing Raman Spectroscopy for Enhanced Accuracy in Phosphoric Acid Systems journal March 2020
Overcoming Oxidation State-Dependent Spectral Interferences: Online Monitoring of U(VI) Reduction to U(IV) via Raman and UV–vis Spectroscopy journal April 2020
Decomposition of the Experimental Raman and Infrared Spectra of Acidic Water into Proton, Special Pair, and Counterion Contributions journal October 2017
Sensor Fusion: Comprehensive Real-Time, On-Line Monitoring for Process Control via Visible, Near-Infrared, and Raman Spectroscopy journal July 2020
Online Monitoring of Solutions Within Microfluidic Chips: Simultaneous Raman and UV–Vis Absorption Spectroscopies journal August 2019
142. A spectrophotometric study of the nitrate complexes of uranium(IV) journal January 1964
Absorption of Light in Organic Compounds journal October 1934
Probing Uranium(IV) Hydrolyzed Colloids and Polymers by Light Scattering journal March 2014
Spectroscopic monitoring of spent nuclear fuel reprocessing streams: an evaluation of spent fuel solutions via Raman, visible, and near-infrared spectroscopy journal September 2011
Spectrophotometric Determination of Plutonium in Highly Radioactive Liquid Waste Using an Internal Standardization Technique with Neodymium(III) journal January 2008