Title: Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography

Abstract

Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments, and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro channel plate) to provide gating and high DQE at the 40–200keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Here, experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.

Authors:
 [1];  [1]; ORCiD logo [1];  [1];  [1];  [1];  [1];  [1];  [1];  [1];  [2];  [2];  [1];  [1];  [1];  [1];  [1];  [1]
  1. Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
  2. National Security Technologies, Livermore, CA (United States)
Publication Date:
Research Org.:
Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
Sponsoring Org.:
USDOE
OSTI Identifier:
1258550
Report Number(s):
LLNL-PROC-694818
Journal ID: ISSN 0034-6748; RSINAK
Grant/Contract Number:  
AC52-07NA27344
Resource Type:
Accepted Manuscript
Journal Name:
Review of Scientific Instruments
Additional Journal Information:
Journal Volume: 87; Journal Issue: 11; Conference: Proceedings of the 21st Topical Conference on High-Temperature Plasma Diagnostics, Madison, WI (United States), 5-9 Jun 2016; Journal ID: ISSN 0034-6748
Publisher:
American Institute of Physics (AIP)
Country of Publication:
United States
Language:
English
Subject:
71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSICS

Citation Formats

Hall, G. N., Izumi, N., Landen, O. L., Tommasini, R., Holder, J. P., Hargrove, D., Bradley, D. K., Lumbard, A., Cruz, J. G., Piston, K., Lee, J. J., Romano, E., Bell, P. M., Carpenter, A. C., Palmer, N. E., Felker, B., Rekow, V., and Allen, F. V. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography. United States: N. p., 2016. Web. doi:10.1063/1.4959948.
Hall, G. N., Izumi, N., Landen, O. L., Tommasini, R., Holder, J. P., Hargrove, D., Bradley, D. K., Lumbard, A., Cruz, J. G., Piston, K., Lee, J. J., Romano, E., Bell, P. M., Carpenter, A. C., Palmer, N. E., Felker, B., Rekow, V., & Allen, F. V. Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography. United States. https://doi.org/10.1063/1.4959948
Hall, G. N., Izumi, N., Landen, O. L., Tommasini, R., Holder, J. P., Hargrove, D., Bradley, D. K., Lumbard, A., Cruz, J. G., Piston, K., Lee, J. J., Romano, E., Bell, P. M., Carpenter, A. C., Palmer, N. E., Felker, B., Rekow, V., and Allen, F. V. Wed . "Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography". United States. https://doi.org/10.1063/1.4959948. https://www.osti.gov/servlets/purl/1258550.
@article{osti_1258550,
title = {Spatial resolution measurements of the advanced radiographic capability x-ray imaging system at energies relevant to Compton radiography},
author = {Hall, G. N. and Izumi, N. and Landen, O. L. and Tommasini, R. and Holder, J. P. and Hargrove, D. and Bradley, D. K. and Lumbard, A. and Cruz, J. G. and Piston, K. and Lee, J. J. and Romano, E. and Bell, P. M. and Carpenter, A. C. and Palmer, N. E. and Felker, B. and Rekow, V. and Allen, F. V.},
abstractNote = {Compton radiography provides a means to measure the integrity, ρR and symmetry of the DT fuel in an inertial confinement fusion implosion near peak compression. Upcoming experiments at the National Ignition Facility will use the ARC (Advanced Radiography Capability) laser to drive backlighter sources for Compton radiography experiments, and will use the newly commissioned AXIS (ARC X-ray Imaging System) instrument as the detector. AXIS uses a dual-MCP (micro channel plate) to provide gating and high DQE at the 40–200keV x-ray range required for Compton radiography, but introduces many effects that contribute to the spatial resolution. Here, experiments were performed at energies relevant to Compton radiography to begin characterization of the spatial resolution of the AXIS diagnostic.},
doi = {10.1063/1.4959948},
journal = {Review of Scientific Instruments},
number = 11,
volume = 87,
place = {United States},
year = {Wed Aug 03 00:00:00 EDT 2016},
month = {Wed Aug 03 00:00:00 EDT 2016}
}

Journal Article:
Free Publicly Available Full Text
Publisher's Version of Record

Citation Metrics:
Cited by: 3 works
Citation information provided by
Web of Science

Save / Share:

Works referenced in this record:

Development of a dual MCP framing camera for high energy x-rays
journal, November 2014

  • Izumi, N.; Hall, G. N.; Carpenter, A. C.
  • Review of Scientific Instruments, Vol. 85, Issue 11
  • DOI: 10.1063/1.4891712

Range distributions and projected ranges of 0.1- to 100-MeV electrons in elemental absorbers
journal, January 1996

  • Tabata, Tatsuo; Andreo, Pedro; Shinoda, Kunihiko
  • Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms, Vol. 108, Issue 1-2
  • DOI: 10.1016/0168-583X(95)00625-7

Development of Compton radiography of inertial confinement fusion implosions
journal, May 2011

  • Tommasini, R.; Hatchett, S. P.; Hey, D. S.
  • Physics of Plasmas, Vol. 18, Issue 5
  • DOI: 10.1063/1.3567499

AXIS: An instrument for imaging Compton radiographs using the Advanced Radiography Capability on the NIF
journal, November 2014

  • Hall, G. N.; Izumi, N.; Tommasini, R.
  • Review of Scientific Instruments, Vol. 85, Issue 11
  • DOI: 10.1063/1.4892558

Characterization of the series 1000 camera system
journal, October 2004

  • Kimbrough, J. R.; Moody, J. D.; Bell, P. M.
  • Review of Scientific Instruments, Vol. 75, Issue 10
  • DOI: 10.1063/1.1789261

Calibrating of x-ray detectors in the 8 to 111 keV energy range and their application to diagnostics on the National Ignition Facility
conference, October 2012

  • Lee, Joshua J.; Haugh, Michael J.; LaCaille, Greg
  • SPIE Optical Engineering + Applications, SPIE Proceedings
  • DOI: 10.1117/12.930162

Recent advances in gated x-ray imaging at LLNL
conference, January 1991

  • Wiedwald, Jay D.; Bell, Perry M.; Kilkenny, Joseph D.
  • San Diego '90, 8-13 July, SPIE Proceedings
  • DOI: 10.1117/12.23370

Microchannel plate detectors
journal, June 1979


Improved measurements of noise and resolution of x-ray framing cameras at 1–2 keV
journal, March 2000

  • Pawley, Carl J.; Deniz, A. V.
  • Review of Scientific Instruments, Vol. 71, Issue 3
  • DOI: 10.1063/1.1150497

Progress on converting a NIF quad to eight, petawatt beams for advanced radiography
journal, August 2010


Works referencing / citing this record:

The Crystal Backlighter Imager: A spherically bent crystal imager for radiography on the National Ignition Facility
journal, January 2019

  • Hall, G. N.; Krauland, C. M.; Schollmeier, M. S.
  • Review of Scientific Instruments, Vol. 90, Issue 1
  • DOI: 10.1063/1.5058700