Coherent Soft X-ray Diffraction Imaging of Coliphage PR772 at the Linac Coherent Light Source
Abstract
A dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source.
- Authors:
- Publication Date:
- Other Number(s):
- CXIDB ID 58
- DOE Contract Number:
- AC02-05CH11231
- Research Org.:
- Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States). Coherent X-ray Imaging Data Bank; Uppsala University, SLAC National Accelerator Laboratory, CFEL, University of Hamburg, Arizona State University, University of Wisconsin, La Trobe University
- Sponsoring Org.:
- Uppsala University, SLAC National Accelerator Laboratory, CFEL, University of Hamburg, Arizona State University, University of Wisconsin, La Trobe University
- Keywords:
- XFEL; AMO; Coliphage PR772; X-ray Free-electorn Lasers; Single Particle X-ray Diffraction Imaging; LCLS
- OSTI Identifier:
- 1349664
- DOI:
- https://doi.org/10.11577/1349664
Citation Formats
Reddy, Hemanth, K.N. Coherent Soft X-ray Diffraction Imaging of Coliphage PR772 at the Linac Coherent Light Source. United States: N. p., 2017.
Web. doi:10.11577/1349664.
Reddy, Hemanth, K.N. Coherent Soft X-ray Diffraction Imaging of Coliphage PR772 at the Linac Coherent Light Source. United States. doi:https://doi.org/10.11577/1349664
Reddy, Hemanth, K.N. 2017.
"Coherent Soft X-ray Diffraction Imaging of Coliphage PR772 at the Linac Coherent Light Source". United States. doi:https://doi.org/10.11577/1349664. https://www.osti.gov/servlets/purl/1349664. Pub date:Thu Jan 05 00:00:00 EST 2017
@article{osti_1349664,
title = {Coherent Soft X-ray Diffraction Imaging of Coliphage PR772 at the Linac Coherent Light Source},
author = {Reddy, Hemanth, K.N.},
abstractNote = {A dataset of coherent soft X-ray diffraction images of Coliphage PR772 virus, collected at the Atomic Molecular Optics (AMO) beamline with pnCCD detectors in the LAMP instrument at the Linac Coherent Light Source.},
doi = {10.11577/1349664},
journal = {},
number = ,
volume = ,
place = {United States},
year = {2017},
month = {1}
}
Save to My Library
You must Sign In or Create an Account in order to save documents to your library.
Works referencing / citing this record:
Coherent soft X-ray diffraction imaging of coliphage PR772 at the Linac coherent light source
journal, June 2017
- Reddy, Hemanth K. N.; Yoon, Chun Hong; Aquila, Andrew
- Scientific Data, Vol. 4, Issue 1