Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Scaling of the Resolving Power and Sensitivity for Planar FAIMS and Mobility-Based Discrimination in Flow- and Field- Driven Analyzers

Journal Article · · Journal of the American Society for Mass Spectrometry, 18(9):1672–1681
Continuing rapid development of the technology and applications of field asymmetric waveform ion mobility spectrometry (FAIMS) calls for better understanding of the limitations of this method and factors that govern them. While key performance metrics such as resolution and ion transmission efficiency had been calculated for specific cases using numerical simulations, the underlying physical trends remained obscure. Here we determine that the resolving power of planar FAIMS scales as the square root of separation time and sensitivity drops exponentially at the rate controlled by absolute ion mobility and several instrumental parameters. A strong dependence of ion transmission on mobility causes severe discrimination against species with higher mobility, presenting particular problems for analyses of complex mixtures. While the time evolution of resolution and sensitivity is virtually identical in existing FAIMS systems driven by gas flow and proposed devices driven by electric field, the distributions of separation times are not. The inverse correlation between mobility (and thus diffusion speed) and residence time for a particular species in field-driven FAIMS greatly reduces the mobility-based discrimination and provides much more uniform separations.
Research Organization:
Pacific Northwest National Laboratory (PNNL), Richland, WA (US), Environmental Molecular Sciences Laboratory (EMSL)
Sponsoring Organization:
USDOE
DOE Contract Number:
AC05-76RL01830
OSTI ID:
917958
Report Number(s):
PNNL-SA-55353; 20496; 400412000
Journal Information:
Journal of the American Society for Mass Spectrometry, 18(9):1672–1681, Journal Name: Journal of the American Society for Mass Spectrometry, 18(9):1672–1681 Journal Issue: 9 Vol. 18; ISSN 1044-0305; ISSN JAMSEF
Country of Publication:
United States
Language:
English

Similar Records

Improving FAIMS Sensitivity using a Planar Geometry with Slit Interfaces
Journal Article · Tue Sep 01 00:00:00 EDT 2009 · Journal of the American Society for Mass Spectrometry, 20(9):1768-1774 · OSTI ID:965561

High-Resolution Field Asymmetric Waveform Ion Mobility Spectrometry Using New Planar Geometry Analyzers
Journal Article · Thu Jun 01 00:00:00 EDT 2006 · Analytical Chemistry, 78(11):3706-3714 · OSTI ID:885457

Modeling the Resolution and Sensitivity of FAIMS analyses
Journal Article · Fri Oct 01 00:00:00 EDT 2004 · Journal of the American Society for Mass Spectrometry · OSTI ID:15011110