Effect of vacuum chamber eddy current and compensation by digital feedback
Measurement of the effect of the eddy current induced in the APS storage ring vacuum chamber by the storage ring sextupole magnet and its compensation using digital feedback with proportional, integral, and derivative (PID) control algorithm are presented. The magnetic field in the vacuum chamber shows strong quadrupole and sextupole components varying with frequency, in addition to significant attenuation and phase shift. Large changes in the magnet resistance and inductance were also observed. Development of a theory of digital feedback to obtain system responses and the conditions for optimal control will be described, in conduction with design of a digital filter to compensate for the eddy current effect.
- Research Organization:
- Argonne National Lab., IL (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- W-31109-ENG-38
- OSTI ID:
- 89493
- Report Number(s):
- LS--209; ON: DE95015387
- Country of Publication:
- United States
- Language:
- English
Similar Records
Compensation for the effect of vacuum chamber eddy current by digital signal processing for closed orbit feedback
Open loop compensation for the eddy current effect in the APS storage ring vacuum chamber
Compensation for the eddy current effect in the APS storage ring vacuum chamber
Conference
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:10175712
Open loop compensation for the eddy current effect in the APS storage ring vacuum chamber
Conference
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5724044
Compensation for the eddy current effect in the APS storage ring vacuum chamber
Technical Report
·
Wed May 30 00:00:00 EDT 1990
·
OSTI ID:378786