Compensation for the eddy current effect in the APS storage ring vacuum chamber

Technical Report ·
DOI:https://doi.org/10.2172/378786· OSTI ID:378786
The amplitude attenuation and the phase shift of the correction magnet field inside the APS storage ring vacuum chamber due to the eddy current effect were measured. A circuit to compensate for this effect was then inserted between the signal source and the magnet power supply. The amplitude was restored with an error of less than 20% of the source signal amplitude and the phase shift was reduced from 80{degrees} to 12{degrees} at 10 Hz.
Research Organization:
Argonne National Lab., IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
W-31109-ENG-38
OSTI ID:
378786
Report Number(s):
LS--148(ANL); ON: DE96015103
Country of Publication:
United States
Language:
English