Antiproton momentum distributions as a measure of electron cooling force at the Fermilab Recycler

Conference ·
OSTI ID:892362

The Fermilab Recycler is a fixed 8 GeV kinetic energy storage ring located in the Fermilab Main Injector tunnel near the ceiling. Electron cooling of high energy antiprotons has recently been demosntrated [1] at the Recycler. Antiproton beam Schottky signals were used to measure the antiproton momentum distribution at equilibrium between a calibrated broadband diffusion source and electron cooling. The large Recycler momentum aperture, the dependence of the electron cooling force as a function of the antiproton momentum deviation and the calibrated diffusion source combine to give a unique sepectral measurement of the antiproton beam momentum distribution.

Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76CH03000
OSTI ID:
892362
Report Number(s):
FERMILAB-CONF-06-203-AD
Country of Publication:
United States
Language: