Antiproton momentum distributions as a measure of electron cooling force at the Fermilab Recycler
Conference
·
OSTI ID:892362
The Fermilab Recycler is a fixed 8 GeV kinetic energy storage ring located in the Fermilab Main Injector tunnel near the ceiling. Electron cooling of high energy antiprotons has recently been demosntrated [1] at the Recycler. Antiproton beam Schottky signals were used to measure the antiproton momentum distribution at equilibrium between a calibrated broadband diffusion source and electron cooling. The large Recycler momentum aperture, the dependence of the electron cooling force as a function of the antiproton momentum deviation and the calibrated diffusion source combine to give a unique sepectral measurement of the antiproton beam momentum distribution.
- Research Organization:
- Fermi National Accelerator Laboratory (FNAL), Batavia, IL
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC02-76CH03000
- OSTI ID:
- 892362
- Report Number(s):
- FERMILAB-CONF-06-203-AD
- Country of Publication:
- United States
- Language:
- English