Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Electron cooling of 8-GeV antiprotons at Fermilab's Recycler: Results and operational implications

Conference ·
OSTI ID:892385

Electron cooling of 8 GeV antiprotons at Fermilab's Recycler storage ring is now routinely used in the collider operation. It requires a 0.1-0.5 A, 4.3 MeV dc electron beam and is designed to increase the longitudinal phase-space density of the circulating antiproton beam. This paper briefly describes the characteristics of the electron beam that were achieved to successfully cool antiprotons. Then, results from various cooling force measurements along with comparison to a nonmagnetized model are presented. Finally, operational aspects of the implementation of electron cooling at the Recycler are discussed, such as adjustments to the cooling rate and the influence of the electron beam on the antiproton beam lifetime.

Research Organization:
Fermi National Accelerator Laboratory (FNAL), Batavia, IL
Sponsoring Organization:
USDOE
DOE Contract Number:
AC02-76CH03000
OSTI ID:
892385
Report Number(s):
FERMILAB-CONF-06-098-AD
Country of Publication:
United States
Language:
English

Similar Records

Commissioning of Fermilab's electron cooling system for 8-GeV antiprotons
Conference · Sun May 01 00:00:00 EDT 2005 · OSTI ID:15017118

Status of high energy electron cooling in FNAL's Recycler Ring
Conference · Fri Sep 01 00:00:00 EDT 2006 · OSTI ID:897043

Electron cooling rates characterization at Fermilab's Recycler
Conference · Fri Jun 01 00:00:00 EDT 2007 · Conf.Proc.C070625:1715,2007 · OSTI ID:922038