The Fermilab Recycler Ring (RR) is intended to be used as a future antiproton storage ring for the Run II proton-antiproton collider operation. It is proposed that about 40mA of antiproton beam from the Accumulator Ring will be transferred to the Recycler once for every two to three hours, stacked and cooled. This operation continues for about 10 to 20 hours depending on the collider needs for antiprotons. Eventually, the cooled antiproton beam will be un-stacked from the Recycler and transferred to the Tevatron via the Main Injector. They have simulated stacking and un-stacking of antiprotons in the Recycler using multi-particle beam dynamics simulation code ESME. In this paper they present results of these simulations.

Research Organization:
Fermi National Accelerator Lab., Batavia, IL (US)
Sponsoring Organization:
US Department of Energy; USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
811813
Report Number(s):
FERMILAB-Conf-03/161
Country of Publication:
United States
Language:
English

Similar Records

Antiproton cooling in the Fermilab Recycler Ring
Conference · Wed Nov 30 23:00:00 EST 2005 · AIP Conf.Proc.821:39-47,2006 · OSTI ID:878992

Beam dynamics simulations for the Fermilab Recycler Ring barrier buckets
Conference · Mon Jun 02 00:00:00 EDT 2003 · OSTI ID:811359

Fermilab Antiproton source, Recycler ring and Main Injector
Technical Report · Fri Mar 22 00:00:00 EDT 2013 · OSTI ID:1127965