Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Failure analysis of rutile sleeves in MC3080 lightning arrestor connectors.

Technical Report ·
DOI:https://doi.org/10.2172/883464· OSTI ID:883464

The purpose of this SAND Report is to document efforts in the extraction and failure analyses of sleeve-style Lightning Arrestor Connectors (LACs). Several MC3080 and MC3079 LACs were recovered from the field and tested as part of the Enhanced Surveillance Campaign. A portion of these LACs failed retesting. Terry Ernest (01733), the LAC Component Engineer, provided eleven MC3080 LACs for evaluation where four of the LACs failed IR/DCW and one failed FRB requirements. The extraction of rutile sleeves from failed LACs was required to determine the source of failure. Rutile sleeves associated with connector function failures were examined for cracks, debris as well as any other anomalies which could have caused the LAC to not function properly. Sleeves that failed FRB or that experienced high FRB exhibited high symmetry, smooth surface, long-flow amicon, and slightly over-sized inside diameter. LACs that failed DCW or IR requirements had rutile sleeves that exhibited breakdown tracks.

Research Organization:
Sandia National Laboratories
Sponsoring Organization:
USDOE
DOE Contract Number:
AC04-94AL85000
OSTI ID:
883464
Report Number(s):
SAND2004-4584
Country of Publication:
United States
Language:
English

Similar Records

Development of a lightning arrestor connector
Technical Report · Mon Dec 31 23:00:00 EST 1973 · OSTI ID:4301936

Lightning Arrestor Connectors Production Readiness
Technical Report · Mon Oct 20 00:00:00 EDT 2008 · OSTI ID:952468

Lightning arrestor connector. Group 2. Evaluation and testing development report