Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Operating experience with a daily-dispatched LM-5000 STIG cogeneration plant

Conference ·
OSTI ID:85999
 [1];  [2]
  1. Stewart and Stevenson Services, Inc., Houston, TX (United States). Gas Turbine Productions Division
  2. Power Magazine, New York, NY (United States)

The Yuba City Cogeneration Plant is a unique facility as it is a daily-dispatched LM-5000 steam injected gas turbine (STIG) that operates only during the peak summer months. This paper discusses the unique design, operation and maintenance requirements of the LM-5000 STIG. Engine operating history and maintenance problems are discussed. Reliability and availability data for the first three summer peak seasons are presented and compared with other cogeneration plant performance data. Calculations are based on North American Reliability Council/Generating Availability Data System (NERC/GADS) as a basis for operating statistic comparisons (1990). The LM-5000 STIG has demonstrated operating reliability and availability under daily cycling operation that is comparable to other base loaded aero-derivative cogeneration plants.

OSTI ID:
85999
Report Number(s):
CONF-941024--; ISBN 0-7918-1213-8
Country of Publication:
United States
Language:
English

Similar Records

Electric utility system benefits of factory packaged GE LM Modular Generator sets
Conference · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:81471

Aeroderivative engine reliability and availability
Journal Article · · Cogeneration and Competitive Power Journal; (United States) · OSTI ID:6770105

Economically dispatching cogeneration facilities
Technical Report · Wed May 01 00:00:00 EDT 1996 · OSTI ID:269593