Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Beam loss, residual radiation, and collimation and shielding in the Fermilab booster

Conference ·
OSTI ID:783057

During its 30 years of operation, the Fermilab Booster has served only as an injector for the relatively low repetition rate proton accelerator complex. With the construction of an 8 GeV target station for the 5 Hz MiniBooNE neutrino beam and rapid multi-batch injection into the Main Injector for the NuMI experiment, the demand for Booster protons will increase dramatically over the next few years. This implies serious constraints on beam losses in the machine. A collimation system and shielding design based on realistic Monte Carlo simulations are presented. A two-stage beam collimation system with local shielding has been designed. It provides adequate protection of the Booster components and environment by localizing operational losses. This loss control is a key to the entire future Fermilab high energy physics program.

Research Organization:
Fermi National Accelerator Lab., Batavia, IL (US)
Sponsoring Organization:
USDOE Office of Energy Research (ER) (US)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
783057
Report Number(s):
FERMILAB-Conf-01/141
Country of Publication:
United States
Language:
English