Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measuring the radon concentration in air meting van de radonconcentratie in lucht

Technical Report ·
OSTI ID:7342802
A simple transportable apparatus for measurement of the radon concentration in the air of a workshop was developed. An air sample is sucked through a filter and the decay curve of the alpha activity is measured. The counting speed 40 min after sampling gives an indication of the radon activity. The apparatus was calibrated by analyzing an analogous decay curve obtained with a big filter and a big air sample, the activity being measured with an anti-coincidence counter. (GRA)
Research Organization:
Rijksverdedigingsorganisatie TNO, Rijswijk (Netherlands). Medisch Biologisch Lab. TNO
OSTI ID:
7342802
Report Number(s):
N-75-33380; MBL-1975-12; IRI-190-75-01
Country of Publication:
United States
Language:
English