Palo Verde nuclear generating station feedwater control system optimization project

Conference · · Transactions of the American Nuclear Society; (United States)
OSTI ID:7074767
 [1]; ;  [2]
  1. Arizona Public Service Co., Phoenix (United States)
  2. Combustion Engineering, Inc., Windosr, CT (United States)

The Pale Verde nuclear generating station (PVNGS) units were originally supplied with central digital feedwater control systems. Arizona Public Service (APS) implemented a program to improve the performance of the system. Recently, the recommended setting changes were implemented in PVNGS Unit 3. The evaluation of the new feedwater control system settings during a 0 to 100% power ascension with 5% master controller setpoint changes and a subsequent unplanned reactor trip showed that the desired performance improvements had been achieved. The computer simulation proved to be an invaluable tool for evaluating the feedwater control system performance and alleviated the need for extensive in-plant testing. An additional benefit provided by the simulation was the ability to provide the operations staff with feedwater control system performance expectations for various transients. The PVNGS Unit 3 feedwater control system is a fully automatic 0 to 100% power control system that requires no operator actions.

OSTI ID:
7074767
Report Number(s):
CONF-911107--
Journal Information:
Transactions of the American Nuclear Society; (United States), Journal Name: Transactions of the American Nuclear Society; (United States) Vol. 63; ISSN TANSA; ISSN 0003-018X
Country of Publication:
United States
Language:
English