Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Pressure calculation for corroded pipe developed

Journal Article · · Oil and Gas Journal; (United States)
OSTI ID:7026170
 [1];  [2];  [3]
  1. ARCO Alaska Inc. (United States)
  2. ARCO Transportation Alaska Inc., Anchorage, AK (United States)
  3. Kiefner and Associates Inc., Columbus, OH (United States)

This paper reports that ARCO Alaska Inc. has developed a method for determining the maximum allowable operating pressure (MAOP) in a corroded pipeline. This method incorporates modifications of the ASME/ANSI B31G criterion to correct for its being overly conservative. The method is based on procedures which allow evaluation of large areas of metal loss, corrosion in some welds, groups of noncontinuous pits and, to a limited extent, the effect of circumferential corrosion.

OSTI ID:
7026170
Journal Information:
Oil and Gas Journal; (United States), Journal Name: Oil and Gas Journal; (United States) Vol. 90:442; ISSN OIGJAV; ISSN 0030-1388
Country of Publication:
United States
Language:
English