Methods of testing HEPA filters with short upstream approaches
Conference
·
OSTI ID:6963737
The design of an air cleaning system to be used in a high gamma radiation field presented unique problems for in-place Dioctyl phthalate (DOP) leak testing. The design required remotely changeable HEPA (High Efficiency Particulates Air) filters in a throw-away, stainless steel housing, located underground in a stainless steel-lined concrete pit. The conventional approach of providing ten duct diameters of upstream mixing for the dispersion of testing the second filter stage in the system. To establish aerosol (DOP) injection ports that could provide mixing in accordance with ANSI N510-80, a full-scale housing was built. The housing and components were built of plexiglas to view the DOP streams. A series of tests were designed in which the following factors were varied: (1) aerosol distributors, (2) aerosol distributor locations, (3) baffle design, and (4) baffle location. DOP concentration measurements were taken immediately upstream of the filters. The uniformity score, as determined by ANSI N510-80, was defined as the larger of maximum minus average divided by average, or average minus minimum divided by the average values of DOP concentration. Three tests met the uniformity score requirement of 0.20, but all three had ten duct diameters of upstream mixing. The type of aerosol distributor, duct length, and flow rate were found to most affect the uniformity score. 5 figs.
- Research Organization:
- Oak Ridge National Lab., TN (USA)
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 6963737
- Report Number(s):
- CONF-880815-1; ON: DE88014552
- Country of Publication:
- United States
- Language:
- English
Similar Records
Evaluation of air assay media by the monodisperse DOP (dioctyl phthalate) smoke test
New wste calcining facility process off-gas filtration system and remote in-place DOP test
Standard method for evaluation of air assay media by the monodisperse DOP (dioctyl phthalate) smoke test
Journal Article
·
Sat Dec 31 23:00:00 EST 1977
· Annu. Book ASTM Stand.; (United States)
·
OSTI ID:5505965
New wste calcining facility process off-gas filtration system and remote in-place DOP test
Conference
·
Sat Dec 31 23:00:00 EST 1977
·
OSTI ID:6633281
Standard method for evaluation of air assay media by the monodisperse DOP (dioctyl phthalate) smoke test
Journal Article
·
Tue Dec 31 23:00:00 EST 1974
· Annu. Book ASTM Stand.; (United States)
·
OSTI ID:7356862
Related Subjects
050800* -- Nuclear Fuels-- Spent Fuels Reprocessing
052001 -- Nuclear Fuels-- Waste Processing
053000 -- Nuclear Fuels-- Environmental Aspects
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
AEROSOLS
AIR CLEANING SYSTEMS
AIR FILTERS
BAFFLES
CARBOXYLIC ACID SALTS
COLLOIDS
CONTROL EQUIPMENT
DISPERSIONS
ELECTROMAGNETIC RADIATION
ENGINEERED SAFETY SYSTEMS
EQUIPMENT
FILTERS
FILTRATION
FLOW REGULATORS
GAMMA RADIATION
GASEOUS WASTES
IONIZING RADIATIONS
LEAK TESTING
NUCLEAR FACILITIES
PARTICLES
PARTICULATES
PERFORMANCE TESTING
PHTHALATES
POLLUTION CONTROL EQUIPMENT
RADIATIONS
REMOVAL
SAMPLING
SEPARATION PROCESSES
SOLS
STANDARDS
TESTING
WASTES
052001 -- Nuclear Fuels-- Waste Processing
053000 -- Nuclear Fuels-- Environmental Aspects
11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS
12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE WASTES FROM NUCLEAR FACILITIES
AEROSOLS
AIR CLEANING SYSTEMS
AIR FILTERS
BAFFLES
CARBOXYLIC ACID SALTS
COLLOIDS
CONTROL EQUIPMENT
DISPERSIONS
ELECTROMAGNETIC RADIATION
ENGINEERED SAFETY SYSTEMS
EQUIPMENT
FILTERS
FILTRATION
FLOW REGULATORS
GAMMA RADIATION
GASEOUS WASTES
IONIZING RADIATIONS
LEAK TESTING
NUCLEAR FACILITIES
PARTICLES
PARTICULATES
PERFORMANCE TESTING
PHTHALATES
POLLUTION CONTROL EQUIPMENT
RADIATIONS
REMOVAL
SAMPLING
SEPARATION PROCESSES
SOLS
STANDARDS
TESTING
WASTES