Operating comparison of absorption and centrifugal chillers
Journal Article
·
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States)
OSTI ID:6829348
- York International, Berkshire (United Kingdom) South Bank Univ., London (United Kingdom)
Previous papers have dealt with the comparisons of absorption and centrifugal chillers and indicated the benefits of using absorption machines. Also, the ideal thermodynamic performances and limitations of absorption cycles have been derived. Nevertheless, the need to update this recent work is necessary for several reasons: utility company tariffs are under continuous review; large, double stage, direct-fired absorption chillers are being introduced into the market; and the CFCs are being phased out. The introduction of direct-fired absorption chillers into the United Kingdom (UK) market indicates that maintenance costs are cheaper than expected. The CFC issue has obliged the market to use alternative refrigerants for centrifugal chillers. For this study, centrifugal chillers using R-134a were considered instead of other refrigerants because of the present market trend, although the use of this refrigerant increases the costs of these types of chillers. A comparative study using R-123 could be considered, but is outside the scope of this present work. In addition, payback periods were calculated in this study for both low voltage and high voltage applications, for when low voltage or high voltage electricity is supplied to the building. The client has the option of installing high voltage substations and switchgear in the building to benefit from lower tariffs from the electric utility companies.
- OSTI ID:
- 6829348
- Journal Information:
- ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States), Journal Name: ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States) Vol. 36:10; ISSN 0001-2491; ISSN ASHRAA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Potential ozone-safe refrigerants for centrifugal chillers
How to convert CFC-12 chillers to HFC-134A
Alternative refrigerant performance: Field test of a nonchlorofluorocarbon chiller at Fort Leonard Wood, MO. Final report
Journal Article
·
Sat Sep 01 00:00:00 EDT 1990
· ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (USA)
·
OSTI ID:6488956
How to convert CFC-12 chillers to HFC-134A
Journal Article
·
Wed Mar 31 23:00:00 EST 1993
· Heating, Piping and Air Conditioning; (United States)
·
OSTI ID:6505347
Alternative refrigerant performance: Field test of a nonchlorofluorocarbon chiller at Fort Leonard Wood, MO. Final report
Technical Report
·
Sat Dec 31 23:00:00 EST 1994
·
OSTI ID:104225
Related Subjects
32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
ABSORPTION REFRIGERATION CYCLE
AIR CONDITIONERS
BUILDINGS
COMPARATIVE EVALUATIONS
COOLING SYSTEMS
ENERGY SYSTEMS
EQUIPMENT
EVALUATION
MACHINERY
PERFORMANCE
REFRIGERATING MACHINERY
VAPOR COMPRESSION REFRIGERATION CYCLE
320106* -- Energy Conservation
Consumption
& Utilization-- Building Equipment-- (1987-)
ABSORPTION REFRIGERATION CYCLE
AIR CONDITIONERS
BUILDINGS
COMPARATIVE EVALUATIONS
COOLING SYSTEMS
ENERGY SYSTEMS
EQUIPMENT
EVALUATION
MACHINERY
PERFORMANCE
REFRIGERATING MACHINERY
VAPOR COMPRESSION REFRIGERATION CYCLE