Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Alternative refrigerant performance: Field test of a nonchlorofluorocarbon chiller at Fort Leonard Wood, MO. Final report

Technical Report ·
OSTI ID:104225

Production of chlorofluorocarbon (CFC) refrigerants will stop permanently by the end of 1995, and air-conditioning and refrigeration (AC/R) systems will have to use alternatives to CFC. The U.S. Army`s AC/R systems have a total cooling capacity of more than 1 million tons; approximately 55 percent of these systems use CFC-based refrigerants. Chillers currently using CFC refrigerants must be replaced or converted to operate with non-CFC refrigerants. The U.S. Army Construction Engineering Research Laboratories (USACERL) and the U.S. Army Center for Public Works (USACPW) are doing research to find an efficient, alternative refrigerant for Army installations. The current project monitored the performance of a non-CFC (R-134a) centrifugal chiller at Fort Leonard Wood (FLW), MO. Performance of this chiller under field conditions was compared with the manufacturer`s published ratings. Operational characteristics of the R-134a chiller were obtained by measuring electrical energy consumption, cooling delivered to the chiller cooling loop, and heat rejected by the condenser. Results indicated an average performance of approximately 0.68 kilowatts per ton (kW/ton) for the study period. The manufacturer`s design projection was 0.73 kW/ton. The performance evaluation of the R-134a system shows that it is an efficient addition to the FLW facility.

Research Organization:
Army Construction Engineering Research Lab., Champaign, IL (United States). Energy and Utilities Systems Div.
OSTI ID:
104225
Report Number(s):
AD-A--292052/8/XAB; CERL-FE--95/09
Country of Publication:
United States
Language:
English

Similar Records

Potential ozone-safe refrigerants for centrifugal chillers
Journal Article · Sat Sep 01 00:00:00 EDT 1990 · ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (USA) · OSTI ID:6488956

R-134a: The best alternative for chillers
Journal Article · Sat May 01 00:00:00 EDT 1993 · ASHRAE Journal (American Society of Heating, Refrigerating and Air-Conditioning Engineers); (United States) · OSTI ID:6405164

How to convert CFC-12 chillers to HFC-134A
Journal Article · Wed Mar 31 23:00:00 EST 1993 · Heating, Piping and Air Conditioning; (United States) · OSTI ID:6505347