Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Methane splitting in the K plant at Heydebreck

Technical Report ·
OSTI ID:6727275
This report consisted of two major topics. The first was methane splitting in equipment for gas for distant transmission. The amount to be split was 3500 m/sup 3//hr methane per system. The temperature in the converter outlet was 850/sup 0/C and the methane was preheated to 650/sup 0/C. The results of this showed oxygen requirements to be 0.487 m/sup 3//m/sup 3/ of methane, steam requirements to be 0.529 kg/m/sup 3/ of methane, condensate requirements to be 0.518 kg/m/sup 3/ of methane, and cooling-water requirements to be 16 kg/m/sup 3/ of methane. The second topic was methane splitting in equipment for long-distance gas with additional indirect cooling. A summary showed the oxygen requirements to be 0.487 m/sup 3//m/sup 3/ of methane, steam requirements to be 0.107 kg/m/sup 3/ of methane, condensate requirements to be 0.526 kg/m/sup 3/ of methane, and cooling-water requirements to be 9.6 kg/m/sup 3/ of methane. The items discussed for each topic included calculations of methane converters, which included oxygen requirements and a heat balance of the converter; cooling of the split gas, which included heat content of the split gas at the catalyst converter outlet and heat exchangers; and the cooler-vaporizer system, which included a heat balance of the water circuit, determination of the amount of water in the cooler-vaporizer, and final cooling. 3 figures.
Research Organization:
I.G. Farbenindustrie, A.G., Ludwigshafen (Germany)
OSTI ID:
6727275
Report Number(s):
TOM-237-1281-1291
Country of Publication:
United States
Language:
English