Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Bias identification in PWR pressurizer instrumentation using the generalized liklihood-ratio technique

Conference ·
OSTI ID:6551561

A method for detecting and identifying biases in the pressure and level sensors of a pressurized water reactor (PWR) pressurizer is described. The generalized likelihood ratio (GLR) technique performs statistical tests on the innovations sequence of a Kalman filter state estimator and is capable of determining when a bias appears, in what sensor the bias exists, and estimating the bias magnitude. Simulation results using a second-order linear, discrete PWR pressurizer model demonstrate the capabilities of the GLR method.

Research Organization:
EG and G Idaho, Inc., Idaho Falls (USA)
DOE Contract Number:
AC07-76ID01570
OSTI ID:
6551561
Report Number(s):
CONF-810605-1
Country of Publication:
United States
Language:
English