An investigation into the losses of benzo(a)pyrene and benzene-soluble material from filters during air sampling

Technical Report ·
OSTI ID:6494416
High-volume static sampling is often used in preference to personal sampling for the collection of atmospheric particulate deposits, especially where low levels of pollutants are expected (for example, in the collection of background samples). Some doubt about the accuracy of the results of high-volume sampling when determining BaP was expressed in a reference in a Federal Register report to a claim that results for BaP concentrations in air obtained by high-volume sampling are 11.7 times lower than those obtained by the use of personal samplers. This investigation compares the losses of benzo(a)pyrene and benzene-soluble material from both high-volume and personal samples at various temperatures.
Research Organization:
British Carbonization Research Association, Chesterfield
OSTI ID:
6494416
Report Number(s):
PB-82-243197
Country of Publication:
United States