Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

A direct radioimmunoassay for aldosterone in plasma

Journal Article · · Clin. Chem. (Winston-Salem, N.C.); (United States)
OSTI ID:6257404

This rapid radioimmunoassay for aldosterone is performed directly on 100 microL of unprocessed plasma, with /sup 125/I-labeled aldosterone as the labeled antigen. Researchers use of steroid-free plasma in preparing the standard curve resulted in an overestimate of aldosterone; this problem was overcome by adding to such plasma a mixture of other steroids to provide a constant steroid/aldosterone ratio. Over a wide range of aldosterone concentrations, results agreed well between the present assay and a routine method involving solvent extraction and paper chromatography (r . 0.85), and sensitivity (20 ng/L) and inter- (10.4%) and intra- (3.9%) assay CVs were better with the present assay. This assay is especially useful for multiple samples and (or) when only small-volume samples are available.

Research Organization:
Department of Endocrinology, Princess Margaret Hospital, Christchurch, New Zealand
OSTI ID:
6257404
Journal Information:
Clin. Chem. (Winston-Salem, N.C.); (United States), Journal Name: Clin. Chem. (Winston-Salem, N.C.); (United States) Vol. 29:2; ISSN CLCHA
Country of Publication:
United States
Language:
English