Recirculating flow analyses of Intermediate Size Inducer Pump (ISIP)
This report documents the recirculation flow analyses for the Intermediate-Size Inducer Pump (ISIP), from which the primary flowrates through the pump were obtained. The front and rear impeller labyrinth seals, which incorporate stepped pockets with slanted and rounded ribs were checked. These seal design features should minimize the impeller labyrinth seal leakages and also provide excellent shutoff head characteristics.
- Research Organization:
- Rockwell International Corp., Canoga Park, CA (USA). Energy Systems Group
- DOE Contract Number:
- AT03-76SF76026
- OSTI ID:
- 6078829
- Report Number(s):
- DOE/SF/76026-T25; N-266TI000003; ON: DE82004217
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)
Operation and maintenance manual addendum to Westinghouse OMM-051-00-005 for intermediate-size inducer pump (ISIP) Model 266
Verification of thermal model for ISIP (Intermediate-Size Inducer Pump)
Technical Report
·
Thu Apr 20 23:00:00 EST 1978
·
OSTI ID:6034075
Operation and maintenance manual addendum to Westinghouse OMM-051-00-005 for intermediate-size inducer pump (ISIP) Model 266
Technical Report
·
Thu Jan 18 23:00:00 EST 1979
·
OSTI ID:6032550
Verification of thermal model for ISIP (Intermediate-Size Inducer Pump)
Technical Report
·
Thu Mar 08 23:00:00 EST 1979
·
OSTI ID:5918904