Verification of thermal model for ISIP (Intermediate-Size Inducer Pump)
Technical Report
·
OSTI ID:5918904
A thermal nodal (TAP) model has been set up to represent the ISIP (Intermediate-Size Inducer Pump). Verification of the model has been made by running three cases and comparing results with the FFTF pump tests and Westinghouse's predictions for those tests. The AI-calculated results show generally good agreement with the test measurements.
- Research Organization:
- Rockwell International Corp., Canoga Park, CA (USA)
- DOE Contract Number:
- AT03-76SF76026
- OSTI ID:
- 5918904
- Report Number(s):
- DOE/SF/76026-T47; N-266TI000-007; ON: DE81026265
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)
Rotordynamics of the intermediate size inducer pump (ISIP)
Intermediate-size inducer pump (ISIP-II) test program in SPTF. Final report
Technical Report
·
Thu Apr 20 23:00:00 EST 1978
·
OSTI ID:6034075
Rotordynamics of the intermediate size inducer pump (ISIP)
Technical Report
·
Tue Feb 28 23:00:00 EST 1978
·
OSTI ID:6252218
Intermediate-size inducer pump (ISIP-II) test program in SPTF. Final report
Technical Report
·
Sun Apr 04 23:00:00 EST 1982
·
OSTI ID:707137