Intermediate-size inducer pump (ISIP-II) test program in SPTF. Final report
This report presents the results of a test program of the Intermediate-Size Inducer Pump II (ISIP-II). The program objective was to develop LMFBR technology. This was accomplished by testing an intermediate-size inducer pump in sodium. The FFTF primary pump was used as the basic test article. The FFTF pump was modified to accommodate an inducer-impeller combination and diffuser. The overall test program includes pump assembly, installation, testing, removal from the test loop, disassembly, and final inspection of the entire pump. This report covers only the pump assembly, installation, and testing aspects of the program.
- Research Organization:
- Rockwell International Corp., Canoga Park, CA (United States). Energy Technology Engineering Center
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- AC03-76SF00700
- OSTI ID:
- 707137
- Report Number(s):
- ETEC--81-14; ON: TI82013133
- Country of Publication:
- United States
- Language:
- English
Similar Records
Pump, sodium, inducer, intermediate size (ISIP) (impeller/inducer/diffuser retrofit)
Sodium testing of intermediate-size inducer pump in SPTF at ETEC
Recirculating flow analyses of Intermediate Size Inducer Pump (ISIP)