Heat-transfer performance of a corrugated-tube thermosiphon. Part 1; Evaporator performance

Journal Article · · Heat Transfer - Japanese Research; (United States)
OSTI ID:6063117
 [1];  [2];  [3]; ; ;  [4]
  1. Tokyo Metropolitan Inst. of Technology (JP)
  2. Univ. of Osaka Prefecture (JP)
  3. Nissan Motor Co., Ltd. (JP)
  4. Takuma Research and Development Co., Ltd. (JP)
Two-phase closed thermosiphons are highly efficient heat-transfer elements with applications in terrestrial heat-transport and heat-recovery systems. In this paper, a corrugated copper tube was used as the container of the thermosiphons and distilled water was used as the working fluid. The influences of the liquid charge ratio and inclination angle on the heat-transfer performance were studied. It was found that the optimum liquid charge ratio to evaporator volume is 40 percent and the maximum performance is obtained at an inclination angle of 30 degrees. A useful formula to calculate the heat-transfer coefficient in the evaporator has been derived.
OSTI ID:
6063117
Journal Information:
Heat Transfer - Japanese Research; (United States), Journal Name: Heat Transfer - Japanese Research; (United States) Vol. 20:2; ISSN 0096-0802; ISSN HTJPA
Country of Publication:
United States
Language:
English