Title: Determining rhenium in weak processing solutions

Journal Article · · Ind. Lab. (Engl. Transl.); (United States)
OSTI ID:6037775

Analytical methods of determining rhenium in production solutions and solid materials almost always include a stage of separating molybdenum, since these elements occur together in molybdenum ores and concentrates. The authors have developed a method of analysis for rhenium in low-concentration industrial solutions containing a complicated set of impurities. The molybdenum is separated from rhenium in a separating funnel and the acidity is brought to 1 M. A 20% solution of KCNS is added together with ascorbic acid. The funnel is shaken for 1-2 min and left to stand until the molybdenum is completely reduced (5-10 min), and then the thiocyanate complex of the molybdenum is extracted with diethyl ether. The lower water layer is transferred to a volumetric flask and the necessary reagents are added to reduce the rhenium and produce the yellow-orange rhenium thiocyanate complex. The peak optical density of the complex is measured with a photocolorimeter and the absorption spectra are recorded with a spectrophotometer.

Research Organization:
Institute of General and Inorganic Chemistry, Kiev, USSR
OSTI ID:
6037775
Journal Information:
Ind. Lab. (Engl. Transl.); (United States), Vol. 52:3; Other Information: Translated from Zavod. Lab.; 52: No.3, 7-9(Mar 1986)