Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Comparability and precision of serum PCB measurements

Journal Article · · Arch. Environ. Health; (United States)
The 95% prediction interval for single measurements of serum Aroclor reported by a reputable commercial analyst was found to be approximately +/-42%. The geometric mean serum PCB levels in a population of capacitor workers who had formerly had direct exposure to the commercial PCBs - Aroclors 1016, 1242, and 1254 - were found to be alternatively reportable as 1905 ppb minimum initial PCBs (as calculated from most persistent peaks present); 1093 ppb non-overlapping analytical Aroclor levels (as calculated by the conventional sum-of-the-peak-heights method); 303 ppb total PCBs actually present; or 19 ppb human PCB (as calculated by the NHMP procedure). The broad spread in reportable values was relatable to the PCB isomer distribution and clearance patterns in the occupationally exposed population.
Research Organization:
General Electric Research and Development Center, Schenectady, NY
OSTI ID:
5525745
Journal Information:
Arch. Environ. Health; (United States), Journal Name: Arch. Environ. Health; (United States) Vol. 40:1; ISSN AEHLA
Country of Publication:
United States
Language:
English